USING THE BOILER
Initial start
The commissioning and first boiler startup must be done by an
authorized servicer, otherwise, the warranty will not be valid.
During the first startup, condensation and leakage may occur. This is a natural occurrence
and is not a reason for concern. It is only necessary to wipe the condensate with a dry
cloth.
Protecting the return line
The boiler should be fitted with the protection of the return line. The return temperature
should be between 55 ° C and 60 ° C, thus preventing the formation of tar and forming
the condensate inside the boiler, and therefore prolonging the life of the boiler.
Cleaning and maintenance of the boiler
To ensure the flawless operation of the boiler, it must be cleaned and maintained regularly. A
dirty boiler will have a higher consumption of pellet, so regular cleaning will automatically
reduce the heating costs.
The cleaning is divided into regular and periodic. Regular cleaning means removing the ash
from the box and checking of the burner grid contamination. Periodic cleaning is performed
at least once a year (our recommendation is to thoroughly clean the boiler twice - at least
once during the heating season and once after the heating season ends).