Hydraulic diagrams and connection modes for
individual system configurations
The boiler control supports the connection of three (3) circulation
pumps, mixing valve motor, buffer tank and sanitary water tank.
Only qualified service technicians have access to technical parameters
and settings, and can adjust the hydraulic connection.
The operation system will be adjusted according to the conducted
installation.
Electronic regulation supports connection to three heating circuit pumps, ie outputs: P1, P2
and P3.
P1 pump output can be used for the heating circuit 1 or by activating
the buffer for that circuit
P2 pump output can be used for the heating circuit 2 or by activating
the sanitary boiler for that circuit
The pump output P3 can be used for the remaining heating circuit 3.
Motor mixing valve output can be used only for one heating circuit