DE
GB
23
Legionella prevention
Do not use heated water as drinking water.
After prolonged shutdown of the device for example due holiday, the device should be fully heated up
to the maximum temperature (tap at minimum flow) before re-using. It is recom-mended to flush the
pipes for one minute.
5. Trouble shooting
First aid
• Check the leakage protection switch and the fuses.
• Check if any fittings or shower head are affected by the build-up of limescale or dirt.
• See also „Troubleshooting by users“.
Troubleshooting by users
Problem
Cause
Remedy
No hot water.
No electricity.
Check the leakage protection switch
and the fuses in the consumer unit.
Hot water tap is not opened.
Open the hot water tap.
Although the hot water tap is
fully open, the device does not
switch on.
The required minimum flow
to activate the device is not
reached. Dirt or limescale has
built up in the aerators of the
taps or in the shower head.
Increase the flow.
Clean or descale the device.
Fault elimination by a specialist
Problem
Cause
Remedy
The „Red“ stage of the device
does not switch on.
The pressure on the cold wa-ter
pipe is too low.
Clean the cold water strainer.
Fouling.
Kaltwassersieb reinigen.
Although the hot water tap is
fully open, the flow controller
does not activate.
The required minimum flow
to activate the device is not
reached.
Clean the cold water strainer.
The heating system does not
switch on / No hot water.
No electricity.
Check the leakage protection switch
and the fuses in the consumer unit.
Heater faulty.
Measure the resistance of the de-
vice and replace it if necessary.
If the appliance still fails to operate after you have executed this procedure, please inform the customer
service.
Summary of Contents for Elex 18
Page 2: ...3 4 1 2 50mm 100mm 348 100 50 10 390 80 190 1 2 3 4 ...
Page 3: ...max 25mm L1 L2 L3 160mm 30mm 5 6 7 8 ...
Page 25: ......
Page 26: ......
Page 27: ......