Before installing the wall mounted heater, make sure the wall must be capable to supporting the weight of the
heater. Place the mounting bracket in position. The heater shall be firmly and securely attached to the wall.
This appliance must only be used in a well ventilated
area.
The following clearance should be followed:
The heater should not be installed:
- Where heat ignition can cause damage to gas
cylinders/lines
- Near other combustible materials.
- In open locations subject to rain.
Heater should be installed to allow adequate:
- Clearance around air openings to combustion
chamber.
- Clearance from combustible material.
- Provisions for accessibility and clearance for
combustion and ventilating air supply.
Intallation Clearances
Dimension and Clearance Detail
7
WARNING
: MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL,
FROM TOP 500mm / add TGHSHIELD(not included) for 300mm,
SIDE 1000mm, MINIMUM MOUNTING HEIGHT 2000mm.
Note: Additional heat shield (TGHSHIELD) is required for 300mm overhead clearance and it's available at extra cost.
Model Type
Model No
TGH34W N
TGH34W L
Gas Type
NG
ULPG
Gas Pressure
1.00 KPA
2.5 KPA
Gas consumption
34 Mj/h
34 Mj/h
Injector Size
1.4 mm x 4
0.86mm x 4
Hose Connection
Rp 1/2" BSPP 1/2-1/4" NPT
Net W eight
AGA Approval No.
W all Mounted Radiant Gas Heater
8442 G
11.5 kg
W all Mounted
!