background image

13

USE  AND  CARE  INSTRUCTIONS

Never 

test  for  leaks  with  an  open  flame.  Prior  to  first

use,  at  the  beginning  of  each  season,  you  must  check
for  gas  leaks.  Follow  these  three  steps:

Check  For  Gas  Leaks

  WARNING

!

Failure to read and follow the Use and Care
Instructions could result in a fire or explosion
that could cause serious bodily injury, death
or  property damage.

!

Make  a  soap  solution  by  mixing  one  part  liquid
detergent  and  four  parts  water.

1.

2. Pull  the 

black 

string  down  until 

click

  will  be  heard

and  then  release,  then  turn  on  gas  at  source.

1  part  liquid  detergent

4  parts  water

GAS REQUIREMENTS

TGH34WN(NG) Model:

This appliance is for use with Natural Gas only.

Ensure that inlet pressure to the regulator does
not exceed 5.0 Kpa.

The approved inlet pressure to be 1.0 Kpa.

Apply the soap solution to all visible gas connections.
If  bubbles  appear  in  the  soap  solution  the
connections  are  not  properly  sealed.  Check  each
fitting  and  tighten  or  repair  as  necessary.

3.

  WARNING

!

!

If  you  have  a  gas  leak  that  cannot  be  repaired
by  tightening,  turn  off  the  gas  at  the  source,
disconnect  fuel  line  from  your  heater  and  call
(03)

 

9562  3455  or  your  gas  supplier  for  repair

assistance.

TURN ON (Red)

TURN OFF (Black)

NG  Model

ULPG Model

Summary of Contents for HEATSTRIP TGH34WL

Page 1: ...injury or death Read this operating and assembly instruction thoroughly before installing or serving this heater WARNING FOR OUTDOOR AND NON RESIDENTIAL INDOOR USE ONLY THIS APPLIANCE MUST NOT BE INST...

Page 2: ...ep this Instruction Manual for convenient referral and for part replacement You need to contact Thermofilm Australia Pty Ltd 17 Johnston Court Dandenong South Victoria 3175 Australia Telephone 03 9562...

Page 3: ...ever use an open flame to check for leaks 12 Do not use the heater until all visible gas connections have been leak tested Never test for leaks with an open flame Prior to first use at the beginning o...

Page 4: ...hall comply with one of the following 1 An enclosure with walls on all sides but at least one permanent opening at ground level 2 Within a partial enclosure that includes an overhead cover and no more...

Page 5: ...EVICES FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN A FIRE OR EXPLOSION WHICH COULD CAUSE SERIOUS BODILY INJURY DEATH OR PERPERTY DAMAGE DANGER Grill Information Center FREE HELP Thermofi...

Page 6: ...id unnecessary twisting of the flexible hose After the assembly has been secured turn on the gas and check for leaks by brushing a soap and water solution over all connections The presence of bubbles...

Page 7: ...nce around air openings to combustion chamber Clearance from combustible material Provisions for accessibility and clearance for combustion and ventilating air supply Intallation Clearances Dimension...

Page 8: ...1166D Pin 6 x 150mm 1 P05501164B R Cotter Pin 1 S020100223 Bolt M6 x 150mm 1 S411M0606A Wing Nut M6 1 Screwdriver 1 Install heater to Wall Mounting Bracket Pan Head Screw M5x10mm Qty 3 Part S112M05102...

Page 9: ...Parts Diagram 9...

Page 10: ...ket Lower P033510494 1 14 Head Bowl P03351050D 1 15 Heat Deflector P03351034D 1 16 Head Assembly Bracket P03351051D 1 17 Protective Ring P05556002I 1 18 Electric Ignitor P02505032F 1 Gas valve Assembl...

Page 11: ...r 11 Install Heat Deflector Removeall the packing materials Install the Heat Deflector to the Head using 3 Pan Head Screws M5x10mm then tighten all the screws securely 1 Pan Head Screw M5x10mm Qty 3 P...

Page 12: ...4B Wing Nut M6 Qty 1 Part S411M0606A Bolt M6 x 150mm Qty 1 Part S020100223 Install Heater 12 6 Remove the Finger Protective Rings from Trigger Install Red Cord for Trigger ON Black Cord For Trigger OF...

Page 13: ...release then turn on gas at source 1 part liquid detergent 4 parts water GAS REQUIREMENTS TGH34WN NG Model This appliance is for use with Natural Gas only Ensure that inlet pressure to the regulator d...

Page 14: ...onnections Always light the heater standing to the side of the heater never light the heater standing in front 1 Turn on the gas source 2 Pull the red Cord down and click will be heard and continue to...

Page 15: ...ed the heater be operated on high heat after cleaning to ensure the appliance is dry Try this procedure Proper care and maintenance will keep your heater in top operating condition and prolong its lif...

Page 16: ...the manufacturer Thermofilm does not participate in any site related costs or labor expenses incidental to replacement of parts repairing removing installing servicing transportation or handling of p...

Reviews: