4.0 MANUAL OPERATION (in case of emergency, only if remote control is not working)
The unit may be operated by hand if there is a defect in the remote control. To do so, the ignite (piezo)cable of
the receiver must first be removed and carefully slid into the piezo connector on the gas control block.
4.1 Igniting the fire
*
Open the gas shut-off cock that has been installed in the gas pipe to the unit.
*
Press the “
O I
” switch, on the gas control block, in the “
I
” position.
*
Turn the motor button, on the gas control block, completely to the right.
The button will make a "click”
sound.
*
Turn the operating button on the gas control block, into the “
MAN
” position.
A metal circle in the
operating button will become visible.
*
Push the metal circle inwards. For example, with a pen. Gas will now flow to the pilot flame.
*
While keeping the metal circle pressed down, press the (square) piezo button (along the “
O I
” switch)
several times to ignite the pilot flame. You will be able to see whether the pilot flame is burning through
the glass window.
*
If the pilot flame is alight, keep the metal circle pressed down for another 10 seconds and then let go.
Important: If the pilot light extinguishes, one should wait at least 5 minutes before repeating the
aforementioned steps.
*
Turn the operating button to the
ON
position. The burner may or may not ignite, depending on the position
of the motor button.
*
By turning the motor button to the required setting to the left, the burner will ignite and the flame size can
be adjusted.
4.2 Extinguishing the fire
Turn the motor button, on the gas control block, completely to the right.
The button will make a "click” sound.
The burner will turn off. The pilot flame continues to burn.
4.3 Switching the unit off
Press the "
O I
” switch, on the gas control block, in the “
O
” position.
The pilot flame will extinguish.
If the fireplace is not used for an extended period of time, we recommend closing the gas shut-off cock in the
supply line.
Important: If, for whatever reason, the pilot light extinguishes, you must wait 5 minutes before
igniting the pilot light again.
Piezo Button
Piezo connector
(With manual operation)
Control button
Motor button
(in the maximum setting)
Microswitch
“
O I
” switch
8-pole receiver cable
connection
Small metal circle for
manual operation of the
ignition
(Control button in Manual position)
Summary of Contents for Trimline 2050 OH
Page 20: ...Page 20...
Page 32: ...Pag 32 A...
Page 33: ...Pag 33 20 m m B C D E F G...
Page 34: ...Pag 34 I J 50 20 H...
Page 35: ...Pag 35...
Page 36: ...Pag 36...
Page 37: ...Pag 37...
Page 38: ...Pag 38...
Page 39: ...Pag 39...
Page 40: ...Pag 40 Thermocet International B V Laagerfseweg 31 3931 PC Woudenberg www thermocet nl...