2.
SAFETY OF THE UNIT
The unit is fully safeguarded by means of thermo-electric pilot light protection to prevent unforeseen dis-
charge of gas from the main burner.
2.1
Safety
Do not place ceramic burner decoration material or logs against the pilot burner.
Ensure the pilot light is
able to burn freely over the main burner at all times.
Good ignition of the main burner is only guaranteed if
this is the case.
Not adhering to these instructions can lead to dangerous situations.
The unit, complete concentric flue system and flue terminal need to be cleaned and checked annually by a
recognised gas technician/fitter,
so the unit continues to operate safely.
For additional instructions, see
Chapter 10:
Maintenance.
If, for whatever reason, the pilot light extinguishes, you must wait 5 minutes before igniting the pilot light
again.
The unit may not be operated without the glass panel being in place.
It is not permitted to place flammable materials on the ceramic wood inset.
The layout of the main burner with ceramic burner decoration material and wood inset may under no cir-
cumstances be changed or added to.
Light flammable materials, such as nylon clothing or flammable liquids, may not be placed near the unit.
Ensure children and other persons unaware of the operation of a gas unit, are supervised at all times when
near the unit.
Use a fireguard to protect against burns and protection of the children and persons named above.
Summary of Contents for Trimline 2050 OH
Page 20: ...Page 20...
Page 32: ...Pag 32 A...
Page 33: ...Pag 33 20 m m B C D E F G...
Page 34: ...Pag 34 I J 50 20 H...
Page 35: ...Pag 35...
Page 36: ...Pag 36...
Page 37: ...Pag 37...
Page 38: ...Pag 38...
Page 39: ...Pag 39...
Page 40: ...Pag 40 Thermocet International B V Laagerfseweg 31 3931 PC Woudenberg www thermocet nl...