11.3 Fitting the ceramic log set (see page 35 to 38)

  

 

Attention! Before placing the Ceramic log set.

 

With use of gas category G25 20-25 mBar (I2L, I2ELL) mount the primary aeration bracket under the burner 

 

setting for a good fire image.  

 

method:  

*  

Take the Decoration plate and burner out from 

 

the unit.  

*  

Remove screws from the burner at the venturi.  

*  

Mount the aeration bracket with the removed 

 

screws on the burner as shown.  

*  

Return Burner and decorations back in place. 

 

 

Please note: when installing the log set and the various glowing materials and accessories, the 
following must be taken into account:

  

Keep the opening between the burner and the burner plate free of glowing material 

There should be no glowing material in or on the pilot burner. 

Ceramic materials should not come into contact with the cord of the window fixture. 
Remove this if necessary. The window may otherwise be damaged. 

Mix the glowing material (lava granules) and the “fusilli” (spiral-shaped ceramic material) and spread them 
evenly over the burner and the burner plate so that they are just covered. Glowing embers can be placed 
here and there as decoration. 

 

NOTE

: the remaining material can be discarded. The use of  too much glowing material can adversely 

affect the combustion process. 

 

Place the ceramic wood blocks in the correct order as shown on Pag. 33 t / m 35. 

Place the logs carefully. Other location can seriously affect the flames or malfunction of the burnproces 

 

(explode) 

Before replacing the window make sure if ther must be a restriction plate to be placed or not. 

 

See page 23 and "Table of concentric tracks" on page 28 

If there is a restriction is required for your situation, remove the baffle plate by unscrewing it from the front 

 

of the plate after the plate backwards and then out to be taken. Now install the restrictor plate with two 

 

screws and replace the baffle plate. 

Now place the two windows in reverse order as described on page 23

.

  

 
 
 
 

 

 

 

 

MAKE SURE THE PILOT LIGHT REMAINS UNOBSTRUCTED!

 

 

Incorrectly installed ceramic wood blocks and glowing material may have a significant influence on 
the fire image and the burning effect.

 

 

Summary of Contents for Trimline 2050 OH

Page 1: ...Page 1 OPERATING AND INSTALLATION INSTRUCTIONS 1080 Trimline 2050 OH UNITED KINGDOM UK IRELAND IE...

Page 2: ...neral instructions 7 Concentric flue system Page 11 7 1 Components of the concentric flue system 7 2 Construction of concentric flue system 7 3 Installation instructions regarding existing flues 7 4 P...

Page 3: ...ustion products and correct operation of the different components and functions The flue tube system and the outlets in the outer wall or roof face must also meet the requirements of the applicable re...

Page 4: ...fitter so the unit continues to operate safely For additional instructions see Chapter 10 Maintenance If for whatever reason the pilot light extinguishes you must wait 5 minutes before igniting the pi...

Page 5: ...he factory 3 3 Screen setup After the batteries have been inserted press the OFF button and small at the same time to toggle between F and 12 hour clock and C and 24 hour clock Wait a moment or press...

Page 6: ...ng 3 7 Possible error messages Long sound signals during the ignition Receiver batteries are almost empty After this signal occurs the unit can be switched on approximately another 10x 5 seconds of co...

Page 7: ...eason the pilot light extinguishes you must wait 5 minutes before igniting the pilot light again 3 10 Inserting and replacing the batteries The batteries of the manual transmitter and receiver have a...

Page 8: ...ep the metal circle pressed down for another 10 seconds and then let go Important If the pilot light extinguishes one should wait at least 5 minutes before repeating the aforementioned steps Turn the...

Page 9: ...fireplaces Prevent discolouration of walls and ceilings There are always particles in the air in each living area even if the area is vacuum cleaned regularly These particles are easily visible when t...

Page 10: ...s discussed with the manufacturer There will be air in the gas pipes when the unit is first used The gas pipes therefore need to be vented first Ignite the heater according to operating instructions a...

Page 11: ...for concentric 100 150 and 205 mm for concentric 130 200 in a flammable wall ensure there is 50 mm of extra space around the outer pipe and use fireproof casing and fix the exterior wall duct with th...

Page 12: ...roofing sheet Roof bracket Fire protection plate Bend CC Pipe Wall bracket Bend Floor support Fire protection plate CC Pipe Wall bracket CC Pipe Floor support Fire protection plate CC Pipe Wall brack...

Page 13: ...ists of parts 4 5 and 7 7 5 Installation See page 14 Guide the flexible hose 6 through the existing duct 8 Attach the adapter 5 to the bottom of the flexible hose and secure this in place using 2 park...

Page 14: ...oof pass through 8 Clamping strips 7 Chimney mounting plate Renovation kit 6 Flexible hose 316L 5 Slider renovation kit 4 Inner mounting plate Renovation kit 3 Clamping strips 2 CC Fitted pipe 1 Clamp...

Page 15: ...is may be more difficult if the control is installed using a method that is different from the instructions provided here Please note Only place the batteries after wiring to the receiver gas control...

Page 16: ...lowed immediately by a long beeping signal Release the button Direct the manual transmitter towards the receiver and press the arrow down until you hear a long beeping sound The gas control button wil...

Page 17: ...d label on receiver OK Transmitter receiver range limited 1 Move antenna cable see instructions 2 Replace receiver Optional wall switch cabling not operating properly Replace wall switch cabling Recei...

Page 18: ...eact Press RESET button see instructions Add ground wire between pilot burner and gas valve Do not coil the IGN cable Shorten IGN cable if possible NO IGN sequence stops no pilot flame Transmitter com...

Page 19: ...ver does not react Press RESET button see instructions Add ground wire between pilot burner and gas valve OK Do not coil the IGN cable Shorten IGN cable if possible 7 Main burner is lit NO Gas valve m...

Page 20: ...Page 20...

Page 21: ...21 Name Address Unit serial number Date of purchase Installation date Comments 9 0 MAINTENANCE CHECK LIST Fitter details Service date Performed by Work activities performed Service and maintenance log...

Page 22: ...inspection replace decorative parts exactly as stipulated by the manufacturer Ensure the pilot burner is kept free e check if the pilot flame protection is intact if applicable f check the piezo for...

Page 23: ...t the rear and the sides the unit must have at least 25 mm clearance from fireproof built in materials Install the supplied convection grilles at least 50 cm below the ceiling see page 30 figures 3 4...

Page 24: ...shaped ceramic material and spread them evenly over the burner and the burner plate so that they are just covered Glowing embers can be placed here and there as decoration NOTE the remaining material...

Page 25: ...nition Gas connection 3 8 Internal A Gas intake B Gas exhaust C Thermocouple connection D Pilot burner connection Unit category C11 C31 C91 Pilot flame SIT 3 flames Combustion gas discharge and Combus...

Page 26: ...I2H 1080 G20 G25 G30 31 NO DK ES PT DE IE GB BE FR IT LV SI SK EE HU LT NL DE NL NO DK DE ES PT IE GB BE FR LV SI EE HU LT PL CY MT IT I2H I2E I2E I2l I2ELL I3B P I3 1x 8 1x 5 3x 16 20 20 25 30 37 11...

Page 27: ...pilot flame cannot be adjusted there may be an obstruction in the pilot 2 Check whether the thermocouple interrupter is connected to the gas valve properly 3 Check that the gas valve is not faulty 4...

Page 28: ...aling Wall pass through 1 metre vertical 90 bend max 3 metres horizontal Wall pass through no restriction Roof pass through 2 to 5 metres vertical roof pass through fit 35 mm restriction plate Roof pa...

Page 29: ...Bend 15 30 45 Diameter A B L1 L2 C 100 150 100 150 72 42 15 30 45 130 200 130 200 90 52 15 30 45 THC CC Bend 90 Diameter A B L1 L2 L3 L4 L5 100 150 100 150 72 90 44 145 150 130 200 130 200 87 106 69 1...

Page 30: ...B 100 150 150 208 130 200 200 260 THC CC Bracket Diameter A B 100 150 150 249 130 200 200 300 Diameter A 100 150 150 130 200 200 Diameter A B 100 150 160 300 130 200 210 350 Diameter A B C 100 150 150...

Page 31: ...eter A 100 150 160 130 200 210 THC CC Roofing sheet sloping 45 60 LEAD THC CC Storm collar Diameter A 100 150 160 130 200 210 Diameter A B 100 150 150 50 130 200 200 60 THC CC Wall pas through THC CC...

Page 32: ...Pag 32 A...

Page 33: ...Pag 33 20 m m B C D E F G...

Page 34: ...Pag 34 I J 50 20 H...

Page 35: ...Pag 35...

Page 36: ...Pag 36...

Page 37: ...Pag 37...

Page 38: ...Pag 38...

Page 39: ...Pag 39...

Page 40: ...Pag 40 Thermocet International B V Laagerfseweg 31 3931 PC Woudenberg www thermocet nl...

Reviews: