![Thermocet Trimline 2050 OH Operating And Installation Instructions Download Page 6](http://html1.mh-extra.com/html/thermocet/trimline-2050-oh/trimline-2050-oh_operating-and-installation-instructions_1105507006.webp)
Page 6
3.6 Controls (Remote Control)
Igniting the fire
*
Open the gas shut-off cock that has been installed in the gas pipe to the unit.
*
Press the “
O I
” switch, on the gas control block, in the “
I
” position.
*
Turn the operating button on the gas control block, into the
ON
position.
*
Simultaneously press
OFF
and (large) on the manual transmitter. A short sound signal will confirm
commencement.
Short sound signals will then follow until the pilot flame and main burner are ignited.
After the main burner is ignited, the flame size will automatically move into the maximum setting.
3.7 Possible error messages
*
Long sound signals during the ignition: Receiver batteries are almost empty. (After this signal occurs, the
unit can be switched on approximately another 10x).
*
5 seconds of continuous sound signal: Error message. For example: one of the cables is not connected, the
“
O I
” switch is not in the “
I
” position.
*
5x short sound signal: Ignition of the pilot flame and main burner is unsuccessful.
Possible cause: air in the pilot pipes.
Important
If the pilot light extinguishes, one should wait at least 5 minutes
before repeating the aforementioned steps.
Piezo connector
(With manual
operation)
Control button
Motor button
(in the maximum setting)
Microswitch
“
O I
” switch
8-pole receiver cable
connection
Gas control block (Operating button in ON-position
Summary of Contents for Trimline 2050 OH
Page 20: ...Page 20...
Page 32: ...Pag 32 A...
Page 33: ...Pag 33 20 m m B C D E F G...
Page 34: ...Pag 34 I J 50 20 H...
Page 35: ...Pag 35...
Page 36: ...Pag 36...
Page 37: ...Pag 37...
Page 38: ...Pag 38...
Page 39: ...Pag 39...
Page 40: ...Pag 40 Thermocet International B V Laagerfseweg 31 3931 PC Woudenberg www thermocet nl...