4
OPERATION
4.1
During operation Hot
Do not touch the flue and exhaust opening! The flue and exhaust opening will become hot
during operation!!
4.2
Switching off
To switch off the heating:
1. Switch the rotary switch to position “0”. The pellet supply will stop and the pellets that
are inside the heater will burn out.
Caution
After switching off the convector heater, the ventilator will continue to run. The ventilator will
cool down the convector heater to prevent damage by overheating. The ventilator will
automatically stop. Do not remove the plug from the socket until the fan has stopped
completely.
2. Remove the electrical plug.
To switch off the ventilation:
1.
Switch the rotary switch to position “0”. (See fig. 4.)
2.
Remove the electrical plug.
4.3
Transport after use
1.
Switch off the convector heater and wait until the fan has stopped completely.
2.
Switch off the power supply.
3.
Remove the connection from the room thermostat and place the cap on the
thermostat connection.
4.
Remove the air hoses.
5.
Remove the flue and the exhaust air fan.
6.
Remove the pellet supply hose.
7.
Remove the ash container
0
Off.
Warning: The fan can still start ventilating to prevent overheating
.
1
Ventilation. Only the fan wil run.
2
Automatic heating. The ventilation will start if the temperaure exceeds 40°c.
3
Heating. Ventilation will start immediately.
>40°c
>40°c
Summary of Contents for IMAC 2000 PELLET
Page 2: ...THERMOBILE INDUSTRIES BV INSTRUCTIONMANUAL PELLETHEATER 2 A B C Fig 1 Fig 2 Fig 3 Fig 4 ...
Page 3: ...THERMOBILE INDUSTRIES BV INSTRUCTIONMANUAL PELLETHEATER 3 ...
Page 21: ...THERMOBILE INDUSTRIES BV INSTRUCTIONMANUAL PELLETHEATER 21 APPENDIX E ...
Page 22: ...THERMOBILE INDUSTRIES BV INSTRUCTIONMANUAL PELLETHEATER 22 ...