background image

Installation manual

Daikin Altherma 3 H HT

English

https://daikintechnicaldatahub.eu

Installation manual

Daikin Altherma 3 H HT

EPRA14DAV3
EPRA16DAV3
EPRA18DAV3

EPRA14DAW1
EPRA16DAW1
EPRA18DAW1

Summary of Contents for Altherma 3 H HT Series

Page 1: ...Installation manual Daikin Altherma 3 H HT English https daikintechnicaldatahub eu Installation manual Daikin Altherma 3 H HT EPRA14DAV3 EPRA16DAV3 EPRA18DAV3 EPRA14DAW1 EPRA16DAW1 EPRA18DAW1...

Page 2: ...ll height unrestricted 1000 X X H 150 H 500 500 300 500 500 300 300 1000 500 1000 500 500 1000 500 1000 500 1000 300 X X H X X H General mm 3D124412 300 150 100 Top side obstacle No top side obstacle...

Page 3: ...r de acordo com o previsto em 10 11 12 13 14 15 16 17 18 under iagttagelse af bestemmelserne i enligt villkoren i gitt i henhold til bestemmelsene i noudattaen m r yksi za dodr en ustanoven p edpisu p...

Page 4: ...vastaava kyll stysl mp tila M C Kylm aine N Varmuuspainelaitteen asetus P bar Valmistusnumero ja valmistusvuosi katso mallin nimikilpi Maxim ln p pustn tlak PS K bar Minim ln maxim ln p pustn teplota...

Page 5: ...l Quick guide for basic usage Format Paper in the box of the indoor unit User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital...

Page 6: ...lish Translation General General No top side obstacle No top side obstacle Top side obstacle Top side obstacle Wall height unrestricted Wall height unrestricted The outdoor unit is designed for outdoo...

Page 7: ...2 To install the outdoor unit 1 Carry the unit by its slings and put it onto the installation structure 150 kg 4 2 Fix the unit to the installation structure 4 M12 3 Remove the slings and screws and d...

Page 8: ...on stays 2 and dispose of them 4 Piping installation 4 1 Connecting water piping 4 1 1 To connect the water piping NOTICE Do NOT use excessive force when connecting the field piping and make sure the...

Page 9: ...to air Types of glycol The types of glycol that can be used depend on whether the system contains a domestic hot water tank If Then The system contains a domestic hot water tank Only use propylene gly...

Page 10: ...ECTROCUTION WARNING Rotating fan Before powering ON or servicing the outdoor unit make sure that the discharge grille covers the fan as protection against a rotating fan See 6 2 To install the dischar...

Page 11: ...aker 30 mA field supply 2 Interconnection cable indoor outdoor Route the cable through the frame Connect the wires to the terminal block make sure the numbers match with the numbers on the indoor unit...

Page 12: ...ich is already routed through the frame Connect the wires to the terminal block Fix the cable with a cable tie Use the factory mounted cable Wires 3N GND Maximum running current Refer to name plate on...

Page 13: ...Route the cable through the frame Connect the wires to the terminal block and the earth screw Fix the cable with cable ties Wires 2 GND 0 75 mm Wiring must be double insulated Maximum power allowed fo...

Page 14: ...6 2 To install the discharge grille Install the lower part of the discharge grille 1 Insert the hooks 2 Insert the ball studs 1 2 3 Fix the 2 lower screws 3 2 Install the upper part of the discharge g...

Page 15: ...move the upper part of the discharge grille 4 2 Remove the lower part of the discharge grille 4 3 Rotate the lower part of the discharge grille 4 Align the ball stud and hook on the grille with their...

Page 16: ...illary tube j Distributor k Air heat exchanger l PCB cooling m Accumulator n Muffler E1HHEX Plate heat exchanger heater M1C Compressor M1F Fan motor S1PH High pressure switch 5 6 MPa S2PH High pressur...

Page 17: ...ircuit board ACS A5P Printed circuit board flash BS1 BS4 A1P Push button switch C1 C4 A1P A2P Capacitor DS1 A1P DIP switch E1H Drain tube heater field supply E1HHEX E3HHEX Plate heat exchanger heaters...

Page 18: ...S K2R A4P Magnetic relay E1H K3R A1P Magnetic relay Y3S K4R A1P Magnetic relay E1HC K2M K11M A2P Magnetic contactor L1R L4R Reactor M1C Compressor motor M1F Fan motor PS A2P Switching power supply Q1D...

Page 19: ......

Page 20: ...4P586100 1B 2019 09 Copyright 2019 Daikin 4P586100 1 B 0000000Y...

Reviews: