THERMOBILE INDUSTRIES BV
INSTRUCTIONMANUAL PELLETHEATER
19
APPENDIX C.
EXPLANATION TEMPERATURE CONTROLER Carlo Gavazzi
1.
1 led = okè
Outlet temp >35°C
3.
0061
≠
61°C outlet temp.
0061 = temp. Pt 100 sensor
1.
2 leds
≠
okè
Burner out at 100°C fan still on, wait till temperature is below 80°C
than burner start
automatically. Burner goes on and off, cause is mostly too much
resistance in the outlet.
3.
1.
3 leds + high temperatur lamp on
≠
okè
2.
High temperature.
3.
Burner out and does not start automatically.
4.
Wait till the temperature is
below 80°C and than reset.
1.
1 led + high temperature lamp on
≠
okè
2.
High temperature.
Reset Jumo thermostat.