AGA 111
40.020.955 - rev.
05 - 2017
21
English
Record the maintenance details in table A in
the annex at the back of this manual.
7
SPARE PARTS
Contact the dealer for the use of spare parts.
8
TECHNICAL INFORMATION
•
For technical specifications, see table B
in the annex at the back of this manual.
The heater triggers a
fault; the red lamp on
the operating panel
lights up.
10 The pressure switch
does not switch the
heater off.
Check if the combustion air
fan is rotating.
User
Check if the suction grid is
dirty.
User
Check if the supply of com-
bustion air is sufficient.
User
11 The pressure switch is
defective.
Check the pressure switch
and replace if necessary.
Dealer
12 The ignition is not func-
tioning.
Check the connection
between the transformer and
the electrode for a short cir-
cuit.
Remove any short circuit that
is found.
User
Check the setting of the elec-
trode, see fig. 8.
User
The heater burns too
much gas.
13 There is a leak between
the gas cock and the
gas regulator block.
Shut off the gas supply.
User
Repair the leak.
Dealer
The heater cannot be
switched off with the
switch.
14 The gas regulator block
does not shut off.
Shut off the gas supply and
let the flame burn out.
User
Disconnect the mains con-
nection.
User
Check the gas regulator
block.
Dealer
Fault
Cause
Solution
Action