AGA 111
40.020.955 - rev.
05 - 2017
17
English
4. Connect the heater to the gas supply.
5. Shut the gas cock off and place the gas
pipe under pressure.
6. Check the burner pressure.
7. To connect an outside-air suction device
to the combustion air fan inlet, see
chapter 9.
8. If the heater is provided with a room
thermostat or time clock, connect it to the
appropriate connection (E) of the
operating panel (fig. 5). This connection
has as a rule been provided with a plug
to which the contacts are connected.
9. Insert the plug into the socket.
3.3
Prepare for start-up
3.4
Start up
Heat:
1. Open the gas cock.
2. Switch the selector switch (D) to heat,
see fig. 5.
Ventilate:
1. Switch the selector switch (D) to
ventilate, see fig. 5.
4
USE
4.1
During operation
4.2
Switching off
1. Switch the selector switch to 0.
2. Close the shut-off valve on the gas
supply.
Warning
The heater may only be connected
by suitably authorised people in
accordance with the local standards.
Warning
This check may only be performed by
a suitably authorised person.
The heater is adjusted and regulated
for use on natural gas G25 (I2L).
Reverse the connector in the socket if
the orange indicator lamp (C, fig. 5)
lights up on the operating panel.
The plug must always be accessible.
Check if the heater is correctly
adjusted for the locally-supplied gas
(consult the dealer).
Hot
Do not touch the blower outlet!
The blower outlet becomes hot during
operation!