S.U.B. TK Resistive Quick Start Guide

Quick Start Guide

 

1.1 Orientation and 

Location

Section 1 

Hardware Installation 

The Single-Use Bioreactor hardware is shipped directly from the 

manufacturer and will arrive crated. For unpacking instructions and 

detailed contents of the crate, please refer to the uncrating instructions 

that came with the shipment. Be sure to follow the unpacking instructions 

provided and retain all packaging materials.

Tools Needed:

•  Allen wrench provided in shipping documentation packet 

•  Adjustable wrench needed for leveling feet (not supplied)

a. 

Position reactor and tower in desired location and lock wheels 

ensuring availability of needed utilities (power, gas, etc.). Right or 

left hand orientation was determined at time of order. Ensure that 

tower is located on the same side as the cable and tubing organizer.

 

b. 

Before running cables, note that the cable and tubing organizer 

has an adjustment feature to keep the cables lined up with the 

rear of the control tower. The arm has a slide that can extend and 

retract manually using the clamping knob.

WARNING:

 Any procedures that require the control box to be open 

should be performed with the main electrical disconnect in the locked out 

position and all power sources removed from the control box. For operator 

safety, secure the location of the S.U.B. outer support container  

by disabling the swivel casters before servicing.

Figure 1. 

Cable and Tubing Organizer

Figure 2.

 Cable and Tubing 

Organizer Adjustment Feature

Summary of Contents for HyPerforma S.U.B. TK

Page 1: ...Thermo Scientific HyPerforma S U B TK Resistive Quick Start Guide...

Page 2: ...Thermo Scientific HyPerforma S U B TK Resistive Quick Start Guide Rev 1 0...

Page 3: ...ensuring availability of needed utilities power gas etc Right or left hand orientation was determined at time of order Ensure that tower is located on the same side as the cable and tubing organizer b...

Page 4: ...wer i Overlay Sparge Black ii Micro Sparge Red iii Macro Sparge White Service gas pressure should be a minimum of 30 psi and a maximum of 35 psi for proper operation Verify that gas connections are se...

Page 5: ...B TK System Position and attach various hardware items Secure the tool bracket to the tank This position is not critical but would be convenient near the motor Place the ratchet and the custom open en...

Page 6: ...e use sensors Ensure they are plugged into the back of the control tower DO 1 pH 1 Locate the bag pressure sensor cable on the Tower and route it via the cable management arm and up toward the top arm...

Page 7: ...ctor must be put in place of the UPS cable 1 3 Power Connections UPS Jumper Figure 5 UPS Jumper Ensure the S U B unit is in its intended position Lock the vessel in place by lowering the leveling feet...

Page 8: ...front of the tower is not activated should be in the out position If it is engaged then twist to disengage Note that the E stop light will remain red even though it is disengaged until the next step h...

Page 9: ...he bottom of the BPC Don t remove the protective packaging on top of the BPC at this time 3 Carefully lower the bottom end of the BPC into the S U B with any tubing sets on the top side laying over th...

Page 10: ...the sample line through the snap in slots on the drain coil arm Attach BPC positioning tabs bottom of chamber onto the alignment pins located at the base of the S U B tank Note that the 50 L BPC does...

Page 11: ...hrough the main beam of the cable and tubing organizer using the black snap in features Connect to the correct gas fitting labeled MICRO SPARGE Unclamp this lineset when ready to sparge through frit 9...

Page 12: ...or liquid 13 Position and close a bar clamp Part No SV20664 01 on the bottom drain line as close as possible to the BPC port Figure 11 Also place bar clamps on probe ports intended for conventional p...

Page 13: ...which is admin To type information without plugging a USB keyboard into the control tower click on the miniature keyboard icon located at the bottom middle of the screen This will bring up a touch scr...

Page 14: ...uration File button when first turning on the system Click the tab on the top that reads File Select the appropriate S U B TK system to be used by clicking to highlight it Thermo Turnkey 250L Electric...

Page 15: ...Thermo Scientific 13 S U B TK Resistive Quick Start Guide Quick Start Guide Figure 17 Home Monitor View...

Page 16: ...Guide Quick Start Guide 2012 Thermo Fisher Scientific Inc All rights reserved Cell Culture BioProcessing 925 West 1800 South Logan UT 84321 InAmericas Asia 435 792 8000 435 792 8001fax InEurope 32538...

Reviews: