background image

CO

2

Resistant Shaker

8-1

Thermo Scientific

TH

ERMO

 FISH

ER 

SCIEN

TIFIC 

ST

A

N

D

A

RD

 PRO

D

U

CT 

W

A

RRA

N

TY

The 

W

arranty 

Period 

starts 

two 

weeks 

fr

om 

the 

date 

your 

equipment 

is 

shipped 

fr

om 

our 

facilit

y. 

This 

allows 

for 

shipping 

time 

so 

the 

war

ranty 

will 

go

int

o effect at approximat

ely the same t

ime your equipment is 

deliver

ed. The war

ranty protection extends 

to 

any subsequent

 owner

 during the fir

st year

war

ranty 

period. 

During 

the 

fir

st 

two 

(2) 

years, 

com

ponent 

part

proven 

to 

be 

non-conforming 

in 

mat

erials 

or 

wor

kmanship 

will 

be 

repaired 

or 

rep

laced 

at 

Thermo's

expense, 

labor

 included. 

Inst

allat

ion 

and 

calibr

ation 

are 

not 

covered 

by 

this 

war

ranty 

agreement. 

The 

Technical 

Services 

Depart

ment

 must

 be 

contact-

ed 

for 

war

ranty 

determinat

ion 

and 

dir

ection 

prior

 t

perf

ormance 

of 

any 

repairs. 

Expendable 

it

ems, 

glass, 

filt

ers 

and 

gaskets 

ar

excluded 

fr

om

 t

his

war

ranty

Replacement 

or 

repair 

of 

components 

part

or 

equipment 

under 

this 

war

ranty 

shall 

not 

extend 

the 

war

ranty 

to 

eit

her 

the 

equipmen

or 

to 

the 

compo-

nent 

part 

beyond 

the 

original 

warranty 

period. 

The 

Techni

cal

 Services 

Department 

must 

gi

ve 

prior 

approval 

for 

return 

of 

any 

com

ponents 

or 

equi

pment.

At

 Thermo's 

option, 

all 

non-conforming 

part

must

 be 

returned 

to 

Thermo 

Fisher 

Scientif

ic 

po

sta

ge 

paid 

and 

replacement 

part

ar

shipped 

FOB 

desti-

nation.

TH

IS

 W

ARR

A

NTY

 IS

 EX

C

LU

S

IV

A

ND

 IN 

LIEU

 O

A

LL 

O

TH

ER

 W

ARR

A

NTIES

, W

H

ETH

ER

 W

R

ITTEN, 

O

R

A

O

R

 IMP

LIED

. NO

 W

ARR

A

N

TIES

OF 

MERCHANT

ABI

LITY 

OR 

FITNESS 

FOR 

P

ARTI

CULAR 

PURPOSE 

SHALL 

APPL

Y.

Thermo 

shall 

not 

be 

liable 

for 

any 

indir

ect 

or 

consequent

ial

damages 

including, 

wit

hout 

limit

ation, 

damages 

relat

ing 

to 

lost

 profit

or 

loss 

of 

products.

Your 

loc

al 

Thermo 

Sales 

Of

fice 

is 

ready 

to 

help 

wit

comprehensive 

sit

preparation 

inf

ormat

ion 

before 

your 

equipment 

arr

ives. 

Print

ed 

inst

ruction 

man-

uals 

carefully 

detail 

equipment 

inst

allat

ion, 

operation 

and 

preventive 

maint

enance.

If

 equipment 

service 

 is 

required, 

please 

call 

your 

Technical 

Services 

Depart

ment

 at 

1-800-438-4851 

(USA 

and 

Canada) 

or 

1-740-3

73

-4

76

3. 

W

e'r

re

ad

y

to 

answer 

your 

questions 

on

 e

quipment 

war

ranty

operation, 

maint

enance, 

service 

and 

special 

application. 

 Out

side 

the 

USA, 

cont

act 

your 

local 

dis-

tr

ibut

or 

for 

war

ranty 

inf

ormat

ion.

Re

v. 

 9

/13

Section 8

Warranty Information

Summary of Contents for 88881101

Page 1: ...it us online to register your warranty www thermoscientific com labwarranty User Manual MaxQ 2000 CO2 Plus Digital CO2 Resistant Shaker Catalog 88881101 88881102 88881103 88881104 Operation Manual 0000847 ...

Page 2: ...Thermo Scientific MANUAL NUMBER 0000 847 1 10 28 21 88881127B and 88881181 are introduced TFI 0 0 18 11 2020 Original REV ECR ECN DATE DESCRIPTION By Preface CO2 Resistant Shaker i ...

Page 3: ...spare or replacement parts or provide you with on site service We can also provide you with a quotation on our Extended Warranty for your Thermo Scientific products Whatever Thermo Scientific products you need or use we will be happy to discuss your applications If you are experiencing technical problems working together we will help you locate the problem and chances are correct it yourself over ...

Page 4: ...nstrument 1 6 Overview 2 1 Specifications 2 1 Environmental Conditions 2 2 Safety Tips 2 2 Storing the Signal Cable 2 3 Output Current of Control Box 2 3 Maximum Shaking Speed 2 5 Operation 3 1 Operations on the Control Panel 3 1 Speed and Time Settings 3 2 Alarm System 3 3 Application 4 1 Safety Tips 5 1 Optional Accessories 6 1 Troubleshooting 7 1 Warranty Information 8 1 Section 1 Section 2 Sec...

Page 5: ...iv CO2 Resistant Shaker Thermo Scientific Table of Contents ...

Page 6: ... Thermo Scientific Cat No 88881101 88881102 88881103 88881104 Pictutre Model name on carton box label MaxQ 2000 CO2 Plus 100 240V for USA MaxQ 2000 CO2 Plus 100 240V various plugs MaxQ 2000 CO2 Plus Promotion Package for USA includes CO2 resistant shaker 88881101 Universal Platform and Flask Clamp Starter Kit MaxQ 2000 CO2 Plus Promotion Package for EMEA APAC includes CO2 resistant shaker 88881102...

Page 7: ... USA includes CO2 resistant shaker 88881101 Universal Platform and Flask Clamp Starter Kit MaxQ2000CO2 Plus Promotion Package for EMEA APAC includes CO2 resistant shaker 88881102 Universal Platform Flask Clamp Starter Kit EU Plug N A 1 N A 1 UK Plug N A 1 N A 1 Universal Platform AL N A N A 1 1 100ml Flask Clamp N A N A 2 2 250ml Flask Clamps N A N A 4 4 500ml Flask Clamps N A N A 4 4 1L Flask Cla...

Page 8: ...ll four mounting holes in the universal platform and the four threaded mounting holes are in alignment 3 Fasten the universal platform and the fixed plate with four M4x14 cross recessed countersink head screws CO2 Resistant Shaker 1 3 Thermo Scientific Section 1 Unpacking and Installation Universal Aluminum Platform Installation Figure 1 1 Universal Platform Installation Diagram 1 M4x14 cross rece...

Page 9: ...tall the horizontal universal platform on the fixed plate of the Main body ensure all four mounting holes in the universal platform and the four threaded mounting holes are in alignment 3 Fasten the universal platform and the fixed plate with four M4x14 cross recessed countersink head screws 18 inch Aluminum Platform Installation Figure 1 2 18 inch Platform Installation Diagram 1 M4x14 cross reces...

Page 10: ...mounting holes on the platform and the four threaded mounting holes are in alignment 3 Fasten the platform and the fixed plate with four M4x10 cross recessed countersink head screws 4 Place the rubber mat on the platform Rubber Mat Platform Installation Figure 1 2 Universal Platform Installation Diagram 1 Rubber mat 2 M4x10 cross recessed countersunk head screws 3 Platform 4 Main body of CO2 resis...

Page 11: ... cut off the power first 2 No special cable needed to connect with 4 20mA data port Connections of the Instrument Figure 1 4 Circuit Diagram 1 Main body of CO2 resistant shaker 2 Control box 3 Power adapter 4 Power cord 5 4 20mA data port 1 6 CO2 Resistant Shaker Thermo Scientific Section 1 Unpacking and Installation ...

Page 12: ...imer Range 0 99h 59min Hour Display LED Minute Display LED Dimensions WxDxH Main body 360 x 300 x 96mm 14 2 x 11 8 x 3 8 inch Control Box 213 x 95 x 26mm 8 4 x 3 7 x 1 0 inch Weight Net Weight Main body 17 5 kg 38 58 lbs Net Weight Control Box 0 3 kg 0 66 lbs Gross weight 19 kg 41 9 lbs Power Supply Requirement AC100 240V 50 60Hz Other Certification ROHS WEEE cCSAus CE Mark Noise level 60dB IP Cla...

Page 13: ...e 2 000m Humidity 20 to 99 Non Condensing 1 Unplug and unload before moving the unit 2 This instrument uses a single phase AC100 240V 50 60Hz power supply 3 Remove the power supply when the instrument is in maintenance 4 DO NOT clean the unit with flammable or corrosive liquid 5 Use specified power supply 6 Maximum load 6kg 13 23 lbs 300 rpm 7 To ensure proper operation the unit must be free of su...

Page 14: ...o closing the side plate door to avoid pinching your fingers Section 2 Overview Storing the Signal Cable Figure 2 1 Storing the Signal Cable Diagram 1 Main body of CO2 resistant shaker 2 Slide plate 3 Control box CO2 Resistant Shaker 2 3 Thermo Scientific Orbital Speed vs Output Current Monitoring System Figure 2 2 Output Current Monitoring System 1 Control box 2 Data port ...

Page 15: ...stant Shaker Thermo Scientific Section 2 Overview Orbital Speed vs Output Current Monitoring System Continued Table 2 1 Output current under different speed conditions Speed rpm Output current mA 0 4 30 4 8 300 20 ...

Page 16: ...50 5000ml 5000ml 150 Table 2 2 Maximum Shaking Speed on Rubber Platform in Relation to Flask Size Flask Size Max Flask Capacity Max Speed rpm Size Liquid Volume 50ml 50ml 30 300 100ml 100ml 15 300 150ml 150ml 15 300 200ml 200ml 15 300 250ml 250ml 15 300 500ml 500ml 9 300 1000ml 500ml 4 260 1000ml 4 240 2000ml 1000ml 4 240 2000ml 4 220 3000ml 1500ml 3 250 3000ml 3 220 5000ml 2500ml 1 220 5000ml 1 2...

Page 17: ...atform even if the load is not balanced 2 Please refer to the Liquid Volume table in the specifications section for the maximum load Flask Size Max Flask Capacity Max Speed rpm Size Liquid Volume 50ml 50ml 49 210 100ml 100ml 25 210 150ml 150ml 25 210 200ml 200ml 18 210 250ml 250ml 18 210 500ml 500ml 10 190 1000ml 500ml 7 200 1000ml 7 190 2000ml 1000ml 4 180 2000ml 4 180 3000ml 1500ml 4 160 3000ml ...

Page 18: ...ill decrease splashing of solutions from vessels during operation Warning The microprocessor control system may take 1 minute to synchronize the actual RPM of the universal aluminum platform to the desired RPM setting Make sure that all the flasks and test tubes are firmly fixed on the universal platform and the flask clamps are fasten securely with the screws s Operations on the Control Panel ...

Page 19: ... is running or stopped Speed setting 1 Press RPM TIME key The speed indicator light is lit 2 Press up and down arrow keys to access the speed setting state speed value starts flashing 3 Press up and down arrow keys to change the speed value Speed increases or decreases The minimum unit is 1rpm 4 During settings the unit will reset to current values if no value is input after three seconds 5 Press ...

Page 20: ...y will read end Press any key to place the shaker in standby mode Alarm System 1 During operation the alarm will sound after 10 seconds if the unit has not begun shaking In addition the alarm will sound and stop for the speed over 350 rpm after 2 seconds 2 Once the shaker begins to alarm the RUN indicator light will not be visible and the WARN indicator light will flash and the unit will stop runn...

Page 21: ...3 4 CO2 Resistant Shaker Thermo Scientific Section 3 Operation ...

Page 22: ...o Specifications in Section 2 Application in CO2 Incubator Place the main body of the shaker in the CO2 incubator and use the signal cable to connect the control box through the access port of the CO2 incubator Refer to Figure 4 1 Figure 4 1 Application in CO2 incubator 1 CO2 Incubator 2 Control box 3 Power Cord 4 Main body of CO2 Resistant Shaker ...

Page 23: ...is in operation in the CO2 incubator keep a safe distance from the inner wall of the CO2 incubator to avoid collisions 4 The main body of the shaker should be connected to the control box wire through the access port of the CO2 incubator 5 If the cells are sensitive to vibrations do not put them in the same incubator or on the shaker 4 2 CO2 Resistant Shaker Thermo Scientific Section 4 Application...

Page 24: ... and control box cannot be extended 4 Never modify the supplied power cables 5 Service should only be performed by a qualified professional 6 In the following situations the power supply must be unplugged When the unit is moved When the control box is opened When a fuse is replaced When the equipment is not functioning properly When the equipment is not in use Maintenance Surfaces can be cleaned w...

Page 25: ...liquid has entered the unit remove the platform and clean it 1 Turn off the machine and unplug the power cord 2 Remove the platform with 4 screws 3 Remove top plate with 7 screws 4 Use 70 ETOH to clean the inner area 5 All allow the unit to dry for one hour reassemble unit and operate normally 5 2 CO2 Resistant Shaker Thermo Scientific Section 5 Safety Tips and Maintenance ...

Page 26: ...clamp 88881109 90 90 60 15 500ml clamp 88881110 115 115 70 9 1000ml clamp 88881111 130 130 75 4 2000ml clamp 88881112 170 170 100 4 3000ml clamp 88881113 200 200 140 2 5000ml clamp 88881114 245 245 140 1 500ml Infusion bottle clamp 88881115 100 100 95 6 1000ml Infusion bottle clamp 88881116 125 125 125 4 Funnel Clamp 88881117 N A 2 Fixed Tube rack 40 Ø14mm 88881118 265x120x140 2 Fixed Tube rack 40...

Page 27: ... Tube rack 40 Ø16mm 88881121 285x125x175 2 Universal Aluminum platform 88881122 360x300x5 1 Rubber Mat platform 88881123 360x305x10 N A 96 well microplate holder 88881124 130x90x15 6 Spring Wire Rack 88881125 350X240X80 1 Sticky Mat 88881126 140 140 4 Control Box 88881127B 213 95 26 1 General Power Adaptor N A 1 US Plug 88881129 N A 1 Tabel 6 1 Universal Aluminum Platform Continued 88881128 ...

Page 28: ...WxDxH mm Max Qty Figure CN Plug 88881130 N A 1 EU Plug 88881131 N A 1 UK Plug 88881132 N A 1 Flask Clamp Starter Kit 88881133 N A 1 100ml flask clamp x 2 250ml flask clamps x 4 500ml flask clamps x 4 1L flask clamps x 2 2L flask clamp x 2 Data port 88881181 41X41X41 1 Tabel 6 1 Universal Aluminum Platform ...

Page 29: ...clamp 88881109 90x90x60 18 500ml clamp 88881110 115 115 70 10 1000ml clamp 88881111 130 130 75 7 2000ml clamp 88881112 170 170 100 4 3000ml clamp 88881113 200 200 140 4 5000ml clamp 88881114 245 245 140 2 500ml Infusion bottle clamp 88881115 100 100 95 12 1000ml Infusion bottle clamp 88881116 125 125 125 9 Funnel Clamp 88881117 N A 6 Fixed Tube rack 40 Ø14mm 88881118 265x120x140 4 Fixed Tube rack ...

Page 30: ...e Tube rack 40 Ø16mm 88881121 285x125x175 4 18 inch Aluminum platform 88881122B 457x457x6 1 Rubber Mat platform 88881123 360x305x10 N A 96 well microplate holder 88881124 130x90x15 10 Spring Wire Rack 88881125 350X240X80 1 Sticky Mat 88881126 140 140 9 Control Box 88881127B 213 95 26 1 General Power Adaptor N A 1 US Plug 88881129 N A 1 Tabel 6 2 18 inch Aluminum Platform Continued 88881128 ...

Page 31: ...H mm Max Qty Figure CN Plug 88881130 N A 1 EU Plug 88881131 N A 1 UK Plug 88881132 N A 1 Flask Clamp Starter Kit 88881133 N A 1 100ml flask clamp x 2 250ml flask clamps x 4 500ml flask clamps x 4 1L flask clamps x 2 2L flask clamp x 2 Data port 88881181 41X41X41 1 Tabel 6 2 18 inch Aluminum Platform Continued ...

Page 32: ...ower disconnected Connect the power Power adapter failure Replace power adapter Switched off Switch on No rotating of platform Sensor failure Contact local sales service Main board failure Contact local sales service Loud noise The unit has been placed on uneven surface Place the unit on level and sturdy surface Platform loose Fasten platform Accessories loose Fasten accessories Other Keep record ...

Page 33: ...7 2 CO2 Resistant Shaker Thermo Scientific Section 7 Troubleshooting ...

Page 34: ...beyond the original warranty period The Technical Services Department must give prior approval for return of any components or equipment At Thermo s option all non conforming parts must be returned to Thermo Fisher Scientific postage paid and replacement parts are shipped FOB desti nation THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL OR IMPLIED NO WARRANTIES O...

Page 35: ...8 2 CO2 Resistant Shaker Thermo Scientific Section 8 Warranty Information ...

Page 36: ...her Scientific and its subsidiaries Specifications terms and pricing are subject to change Not all products are available in all countries Please consult your local sales representative for details Thermo Fisher Scientific Asheville LLC 401 Millcreek Road Marietta Ohio 45750 United States A Thermo Fisher Scientific Brand ...

Reviews: