All installations and services must be performed by qualified service personnel.
2
:
If you do not follow these instructions exactly, a fire or explosion may result
causing personal injury, loss of life or property damage.
:
NEVER use gasoline or a mixture of oil and gasoline to start the burner or
furnace.
:
HAZARD OF ASPHYXIATION: Negative pressure inside the closet with closet
door closed and the furnace blower operating shall be no more negative than minus 0.05 inch
water column.
:
Do not obstruct any return air openings, including the return grille on the
furnace. To do so may cause the furnace to activate the high limit and shut down or it may
cause asphyxiation.
:
All local codes and ordinances take precedence with regard to tank and oil lines.
All lines must have shutoff valves, a good pipe joint compound approved for use with oil on
all pipe threads, no kinks, no sharp bends and be properly tested for leaks. Flare fittings are
recommended for tubing.
:
Do not use motor oil or any fuel heavier than No. 2 fuel oil..