43
Electrical Maintenance
Australian Bosch Alternator -
Model 30
120 Amp Charging System
Diagnostic Procedures
NOTE: Units manufactured with
CYCLE-SENTRY and alternators with integral
regulators MUST use replacement alternators
with integral regulators.
Complete the following checkout procedure
before replacing the voltage regulator or the
alternator.
•
When testing alternators use accurate
equipment such as a Thermo King
P/N 204-615 (FLUKE 23) digital multimeter
and a Thermo King P/N 204-613 amp clamp
or an equivalent.
CAUTION: Full-fielding alternators with
the integral regulator is accomplished by
installing a jumper from terminal F2 to
ground. Attempting to full-field the
alternator by applying battery voltage to
terminal F2 will cause voltage regulator
failure.
CAUTION: The F7 fuse must be removed
from the relay board on units equipped
with the Australian Bosch alternator. The
voltage regulator will be damaged if the
unit is turned On with the F7 fuse in place
on the relay board.
1.
Check Point for 2A Amperage
3.
Check Point for Sense Circuit and
Excitation Circuit Voltages
2.
Check Point for B+ Voltage
4.
Position for Full Fielding Jumper
Figure 17: Check Points for Alternator Test
Summary of Contents for 002008
Page 4: ...4 ...
Page 30: ...Unit Description 30 Figure 9 Front View AJA920 ...
Page 31: ...Unit Description 31 1 Access Panels 2 Defrost Damper Figure 10 Back View 1 2 ARA104 ...
Page 114: ...Mechanical Diagnosis 114 ...
Page 116: ...Electric Standby Diagnosis 116 ...
Page 120: ...Remote Evaporator Specifications 120 ...
Page 122: ...Remote Evaporator Maintenance Inspection Schedule 122 ...
Page 128: ...Remote Evaporator Electrical Maintenance 128 ...
Page 132: ...Remote Evaporator Refrigeration Service Operations 132 ...
Page 134: ...Remote Evaporator Structural Maintenance 134 ...
Page 136: ...Remote Evaporator System Diagnosis 136 ...
Page 140: ...Index 140 ...
Page 142: ......
Page 143: ...143 Model 30 Schematic Diagram Page 1 of 2 ...
Page 144: ...144 Model 30 Schematic Diagram Page 2 of 2 ...
Page 145: ...145 Model 30 Wiring Diagram Page 1 of 4 ...
Page 146: ...146 Model 30 Wiring Diagram Page 2 of 4 ...
Page 147: ...147 Model 30 Wiring Diagram Page 3 of 4 ...
Page 148: ...148 Model 30 Wiring Diagram Page 4 of 4 ...
Page 149: ...149 Model 50 Schematic Diagram Page 1 of 2 ...
Page 150: ...150 Model 50 Schematic Diagram Page 2 of 2 ...
Page 151: ...151 Model 50 Wiring Diagram Page 1 of 5 ...
Page 152: ...152 Model 50 Wiring Diagram Page 2 of 5 ...
Page 153: ...153 Model 50 Wiring Diagram Page 3 of 5 ...