background image

 

a

Do not allow children or infirm persons to operate 
this 

THERMITAL THE/TG 3S

 boiler unsupervised.

 

a

Do not operate any electrical devices or equipment, 
including switches or domestic appliances, etc., if 
you can smell fuel or fumes. If you detect any suspi-
cious smells:

-  Ventilate the room by opening all doors and win-

dows.

-  Close the fuel shut-off cock.
-  Report the fault immediately to the 

THERMITAL

 

Technical Assistance Service or a professionally 
qualified heating engineer.

 

a

Do not touch the boiler while barefoot or wet.

 

a

Never clean or service the boiler without first dis-
connecting it from the mains electricity supply 
by turning the main power switch and the control 
panel switch OFF.

 

a

Do not tamper with or adjust the safety or control 
devices without prior authorisation and instructions 
from the boiler’s manufacturer.

The boiler is delivered in separate crates. Check 
that it is complete, undamaged and as ordered as 
soon as you receive it. Report any discrepancies or 
damage to the dealer who sold it.

The

 

THERMITAL THE/TG 3S

 

boiler must be 

installed by a legally qualified heating engineer. 
On completion of the installation, the installer must 
issue the owner with a declaration of conformity 
confirming that the installation has been completed 
to the highest standards in compliance with the 
instructions provided by 

THERMITAL

 in this instruc-

tion manual, and that it conforms to all applicable 
laws and standards.

The boiler must only be used for the purpose speci-
fied by 

THERMITAL

 and for which it is designed. 

The manufacturer declines all responsibility, con-
tractual or other, for damage to property or injury to 
persons or animals caused by improper installation, 
adjustment, maintenance or use.

If you notice any water leaking from the boiler, dis-
connect it immediately from the mains electricity 
supply, shut off the water supply, and notify your 
local 

THERMITAL

 Technical Assistance Centre or a 

qualified heating engineer immediately.

The operation of any appliance that uses fuel, electrical power and water demands that a number of fundamental safety 
precautions be respected.

Periodically check that operating pressure in the 
water circuit is 

over 1 bar

 but below the maximum 

limit specified for the boiler. If this is not the case, 
contact 

THERMITAL

’s Technical Assistance Service 

or a professionally qualified heating engineer.

If the boiler is not going to be used for an extended 
period of time, contact 

THERMITAL

’s Technical 

Assistance Service or a qualified heating engineer 
to have it prepared for shut-down as follows:

- Switch the boiler OFF at the control panel and at the 

mains power switch.

- Close the fuel cock and heating circuit water cock.
- Drain the central heating circuit if there is any risk of 

freezing.

Drain the central heating circuit if there is any risk of 
freezing

This instruction manual is an integral part of the boil-
er. It must be kept safe and must ALWAYS accom-
pany the boiler, even if it is sold to another owner or 
transferred to another user or to another installation.

 

If you damage or lose this manual, order a replace-
ment immediately from your local 

THERMITAL

 

Technical Assistance Centre.

 

a

Never pull, disconnect, or twist the electrical cables 
coming from the boiler even if it is disconnected 
from the mains electricity supply.

 

a

Do not obstruct or restrict the vents in the room 
where the boiler is installed. Adequate ventilation is 
essential for correct combustion.

 

a

Do not expose the boiler to the elements. Do not 
install the boiler outdoors. It is not designed to work 
outdoors and is not fitted with the necessary auto-
matic anti-frost systems to do so.

 

a

Do not switch the boiler off if outdoor temperature 
drops below ZERO (risk of freezing).

 

a

Do not store containers of flammable substances in 
the room where the boiler is installed.

 

a

Do not dispose of packaging material into the envi-
ronment, or leave it within the reach of children, 
since it can become a potential hazard. Dispose of 
packaging material in compliance with applicable 
legislation.

5

ENGLISH

GENERAL

PRECAUTIONS

GENERAL SAFETY INFORMATION

Summary of Contents for 20034707

Page 1: ...THE TG INSTALLATION OPERATION MAINTENANCE AND SYSTEM MANAGEMENT MANUAL...

Page 2: ...are used in conjunction with a fuel oil burner they conform to the Energy Related Products Directive 2009 125 EC and to the EU Delegated Regulation 813 2013 CHARACTERISTICS High efficiency Low emissi...

Page 3: ...uthorised THERMITAL Technical Assistance Centre Their personnel are specially trained to keep your boiler efficient and cheap to run Technical Assistance Centres also stock any original spare parts th...

Page 4: ...s 400 kW 13 Start up 14 SYSTEM MANAGER 14 Temporary shutdown 15 Preparing for extended periods of disuse 16 Cleaning 16 Maintenance 17 Useful information 17 Unpacking the product 18 INSTALLER 18 Overa...

Page 5: ...gineer immediately The operation of any appliance that uses fuel electrical power and water demands that a number of fundamental safety precautions be respected bPeriodically check that operating pres...

Page 6: ...ess Once out of the tube bundle the flue gases pas through a chamber at the rear of the boiler and into the vent flue Their special design with tube bundle over the combus tion chamber makes these boi...

Page 7: ...listed below ACCESSORIES Immersion temperature sensor 1 1 1 1 Solar collector temperature sensor 1 Pipe temperature sensor 1 1 CLIMA COMFORT STANDARD Control by control panel with assistance of access...

Page 8: ...5 M BLU Low NOx 3896010 Modulating 4031197 R Reference burner used during performance qualification tests to derive the technical data declared BURNER THE TG 3S Burner plate Model Code Type 448 511 63...

Page 9: ...ation A supplied with the boiler a aDo not re use old burners if their blast tube lengths are below those specified in the table THE TG 3S 90 115 166 217 255 349 448 511 639 850 1160 1450 L min 128 12...

Page 10: ...lation you MUST apply it in a clearly visible position at the top of one of the side panels If you damage or lose this label order a replacement immediately from THERMITAL s Technical Assistance Servi...

Page 11: ...6 90 3 95 7 90 4 95 9 Useful efficiency at min Pn 80 60 C HCV LCV 89 8 95 2 89 6 95 0 89 9 95 3 90 2 95 6 89 6 95 0 89 9 95 3 Efficiency at rated heat input in Low temperature mode h1 with return at 3...

Page 12: ...8 5 98 5 98 5 98 5 98 5 98 5 Constant pressure drop Pn Max 1 4 1 2 Flue gas temperature T 106 103 103 106 100 106 C Flue gas mass flow rate Pn Max 0 040 0 050 0 072 0 094 0 110 0 151 Kg s Furnace pres...

Page 13: ...t pressure drop Pn Max 1 2 1 0 Flue gas temperature T 104 105 102 108 112 107 C Flue gas mass flow rate Pn Max 0 195 0 221 0 278 0 367 0 507 0 626 Kg s Furnace pressure 2 9 5 4 5 2 6 7 3 9 4 6 mbar Fu...

Page 14: ...s cock and heating water cock are open While the system is still cold check that working pres sure in the water circuit is over 1 bar but below the maximum limit specified for the boiler If the system...

Page 15: ...peration 2 3 times at the most If the prob lem persists after that call THERMITAL s Technical Assistance Service If you need to shut down the system for a short period proceed as follows Turn the cont...

Page 16: ...oapy water to clean the boiler s external casing To remove stubborn marks use a cloth damped in a 50 mix of water and denatured alcohol or a suitable clean ing product Carefully dry the boiler after c...

Page 17: ...MBUSTION EFFICIENCY MEASUREMENTS THERMITAL s Technical Assistance Service is qualified to satisfy these legal requirements and can also provide useful information on MAINTENANCE PROGRAMMES designed to...

Page 18: ...n manual is an integral part of the boiler Once located read it thoroughly and keep it safe 2 THE CASING PANELS complete with assembly accessories 3 THE FRONT COVER to fit on top of the front door IMP...

Page 19: ...60 760 820 820 890 890 1000 1047 1147 1237 mm A1 Base width 580 640 690 690 750 750 790 790 900 980 1070 1160 mm B Depth 1155 1330 1500 1500 1660 1960 2085 2085 2375 2657 2954 3173 mm B1 Base depth 86...

Page 20: ...ty and control devices and to permit easy maintenance b bIf the specific weight of the gas supply to the burn er is greater than the specific weight of air install all electrical parts at least 500 mm...

Page 21: ...d if the quality of the supply recirculation water so demands Refer to the reference values listed in the table alongside REFERENCE VALUES PH 6 8 Electrical conductivity below 200 S cm 25 C Chlorine i...

Page 22: ...8 11 6 7 3 10 15 3 3 3 3 2 17 1 r RTS 3S 0 30 60 90 1 Boiler 2 Central heating manifolds 3 Disconnect valves 4 Pumps 5 Non return valves 6 Automatic vent valve 7 Boiler safety valve 8 Boiler drain co...

Page 23: ...pipe upstream from the water fitting to measure effective water return temperature and control the anti condensate pump or the temperature controller stabilisation function b bAny temperature controll...

Page 24: ...BOILER DOOR HINGES CHANGING THE DIRECTION OF DOOR OPENING The boiler door hinges are factory fitted on the right of the door If you need to reverse the direction of opening remove the boiler s side pa...

Page 25: ...s difficult to align the bolt 6 with the hole in the door slightly loosen the door fixing bolts 1 and lift the door gently to align the hole with the bolt 6 Only lift the door by means of equipment th...

Page 26: ...the opposite side of the door and fix it in place with the safety bolts 4 b bMake sure that the safety bolts 2 and 4 are securely tightened before attempting to open the door Completely unscrew the m...

Page 27: ...lly close the door again by tightening bolts 2 until the door compresses the braided seal Remove the plug 1 taking care not to lose the spring from inside the threaded tube Fit the bracket on the oppo...

Page 28: ...complies with legislation in the country of installation Fit the nut and washer 1 to the earth terminal and tighten the nut 1 2 1 Connect the other end of the cable to the system s earth bar bAnother...

Page 29: ...e bottom rails then hook their top lips over the top rails 1 running between the front and rear heads Secure the side panels in place with the top cross beams 7 and the screws provided Fit your chosen...

Page 30: ...els 4 and 5 in the bottom rails of the base then hook their top lips over the top rails 1 running between the front and rear heads Secure the side panels in place with the top cross beams 7 and the sc...

Page 31: ...P Clip Sensor Sensor Sensor BOILER SAFETY DEVICE sensor Guide b bInsert the sensors belonging to the safety devices into the copper socket P 31 ENGLISH INSTALLER LOCATION OF SENSORS...

Page 32: ...y charged The working pressure in the water circuit is over 1 bar but below the maximum limit specified for the boiler The water circuits have been properly bled The mains power connections to the boi...

Page 33: ...remain in operation until the set temperature is reached If any ignition faults or malfunctions occur the burner performs a LOCKOUT SHUTDOWN This is shown by the red button light on the burner and by...

Page 34: ...If there is any leakage of combustion gases adjust the door as instructed on page Maintenance page 35 Make sure that all the pumps in the system are free and rotate in the right direction Turn off th...

Page 35: ...These bolts are captive in the door and can not be removed b bThe first time you open the door remove the spare hinge assembly B bushing 10 bolt 9 and washer 11 opposite the hinged side of the door AD...

Page 36: ...ols of suitable size and shape to clean inside the tubes Remove any built up deposits from the flue gas box through the access door opening b bIf you are using fuel oil burners with a smoke scale read...

Page 37: ...pipes Boiler and burner mismatched Check specifications and settings Insufficient air fuel flow to burner Check and adjust the burner Control thermostat problem Check the functioning of the thermostat...

Page 38: ...but the radiators are still cold Bleed the circuit Pump malfunctioning Check unseize the pump Problem with minimum tempera ture thermostat if present Check the temperature setting Fumes escaping into...

Page 39: ...39 ENGLISH GENERAL 39...

Page 40: ...ade Riello 7 37045 Legnago VR www thermital it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are there...