background image

If there is scale on TEH, then it can be removed by using scale removing means or mechanically. 
When removing residuals from EWH do not apply excessive force and do not use abrasive cleaners 
not to damage the protective coating of the inner tank.
 
Importance of the first maintenance is that by intensity of scale and residues, magnesium anode 
consumption terms for next maintenance services can be decided and, consequently, service life can 
be  extended.  In  case  of  non-observance  of  the  above  requirements  EWH  service  life  reduces, 
increases the probability of EWH breakdown and validity of warranty expires.

To perform maintenance and replace magnesium anode follow steps:

 

Turn off EWH power. 

џ

Cool hot water or discharge it through the mixer. 

џ

Cut off supply of cold water into EWH. 

џ

Put a rubber hose on the cold water supply inlet pipe or discharge valve and direct the second end to 

џ

the drain. 
Unscrew the relief valve or open drain valve. 

џ

Open a hot water faucet on the mixer. 

џ

Drain water from the EWH through cold water supply inlet pipe or discharge valve. 

џ

Remove  the  protective  cover,  disconnect  wires,  unscrew  and  remove  from  the  casing  the 

џ

removable flange. 
Replace the magnesium anode, clean the TEH if necessary from scale and remove residue. 

џ

To assemble, fill EWH with water and power on. 

џ

When conducting EWH maintenance by forces of special organization the appropriate mark shall be 
made in the warranty card. When replacing the magnesium anode independently by the consumer 
magnesium anode purchase receipt shall be attached to present manual.

Specifying security measures

 

Electrical safety and corrosion protection of EWH are guaranteed only if there is an effective 
earthing in accordance with applicable electric installation rules and regulations.

When installing and operating EWH the following is not allowed:

 

To power EWH if EWH is not filled with water. 

џ

To remove the protective cover when the power is on. 

џ

Use EWH without grounding or use water pipes as grounding. 

џ

To connect EWH to water supply with pressure exceeding 0,6 MPa. (If pressure in the supply 

џ

line is more than 0.6 MPa, an appropriate pressure reducing valve shall be installed at cold 
water  inlet  ahead  of  safety  valve  (not  supplied)  to  reduce  water  pressure  to  normal). 
Installation of pressure reducing valve between EWH and relief valve is forbidden. 
To connect EWH to the water supply without safety valve. 

џ

To drain water from EWH with power switched on.

џ

To use spare parts not recommended by the manufacturer.

џ

To use water from the EWH for cooking.

џ

To  use  water  containing  impurities  (sand,  small  stones),  which  might  lead  to  EWH  and 

џ

safety valve breakdown. 
To modify design and installation dimensions of EWH brackets. 

џ

EN

EN

 Water freezing in the appliance is prohibited because it causes its malfunction which is not a warranty 
case.
 
EWH is not intended to be used by persons with limitations of health, sense or mental limitations, as 
well as persons who are not able to use the EWH, except when it happens under the supervision or 
instructions  by  a  person  responsible  for  EWH  safety.  Children  can  use  EWH  only  under  the 
supervision  of  persons  who  know  how  to  operate  it  safely.  During  EWH  operation,  it  must  be 
inspected regularly for proper health (absence of dripping, burning smell, wiring sparks, etc.). In the 
case of long interruptions in water heater operation, water supply failures, EWH must be disabled and 
cold water inlet valve must be shut off.

Always be aware that there is a risk of hot water scalding and electric shock.

Possible faults and remedies 

If an operational fault occurs EWH shall be disconnected from the mains, water supply shall be cut off.

Apply to a Service center. 

Thermal switch tripped or 
not on.

Powered EWH does 
not heat water. 
No backlights 
of indicator lamps. 

Disconnect EWH from the mains, 
remove EWH protective cover, 
press the safety button until you 
hear a click (

fig. 3

), place the 

cover and turn on power. 

Power cord is damaged. 

There is no voltage in the 
mains

Contact power supply operation 
service 

RCD (if any) tripped

Push RCD restart button. 
Check voltage. 

Frequent tripping of 
thermal switch

The set temperature is close 
to the limit

Turn the thermostat control to 
decrease temperature (

)

Thermostat tube is covered 
with sludge 

Remove the flange and gently 
clean the pipe from the sludge 

Heating time increased 

THE is covered with a layer 
of sludge 

Remove the flange and clean 
the TEH 

Supply voltage decreased

Contact power main operation 
service 

Fault 

Hot water pressure 
from EWH decreased. 
Cold water pressure 
keeps at the level. 

How to fix

Remove the valve and clean it 
in water

Possible cause

Clogged inlet safety valve

22

23

Summary of Contents for Thermo 100 V

Page 1: ...THERMO Models ELECTRIC STORAGE WATER HEATER Series Thermo 30 V Slim Thermo 50 V Slim Thermo 80 V Thermo 100 V Thermo 150 V RU EN UA KZ TR...

Page 2: ......

Page 3: ...1 Fig 1 1 1 Resim 1 1 2 15 12 16 13 9 7 3 14 8 11 4 5 10 6 20 21 22 23 24 25 26 27 18 19 17 3 28...

Page 4: ...sild t js CEBoru eklindeki elektrikli s t c Thermostat Termostat Magnesium anode Magnezyum anot Thermostat control unit Termik ayar kolu Power selection keys i i i G se me klavyesi Temperature indicat...

Page 5: ...nas Hot water inlet valve S cak su vanas Cold water cut off valve So uk su kapama vanas Hot water cut off valve S cak su kapama vanas Cold water main pipe So uk su ana hatt Hot water main pipe S cak s...

Page 6: ...green Sar ye il Yellow Sar 1 5 230 THE 1 5 kW 230 V 1 5 230 1 5 230 Boru eklindeki elektrkli s t c 1 5 kWt 230 V 1 0 230 THE 1 0 kW 230 V 1 0 230 1 0 230 Boru eklindeki elektrkli s t c 1 0 kWt 230 V...

Page 7: ...hing on 10 A 250 V II i i i 10 250 II 10 250 II Tek d meli yuvarlak anahtar al t rma g stergesi ile 10A 250 V rejim II 20 250 95 Temperature limiter 20 A 250 V 95 C 20 250 95 20 250 95 S cakl k s n rl...

Page 8: ...0 05 0 6 230 B 50 2 5 1 2 IPX4 3 40 18 74 5 min max Thermex Thermo 0 150 30 0 8 Thermo Slim 5 1 GP 1 2 1 1 1 RU 8...

Page 9: ...RU 7 8 9 74 5 C 10 93 5 3 11 1 9...

Page 10: ...2 4 0 5 200 17 21 3 5 4 RU Thermo 80 150 Thermo Slim 30 50 10...

Page 11: ...18 17 1 100 24 25 22 23 5 4 I 11 1 RU 11 Power I 1 Power II 2 Thermo Thermo Slim 1 5 1...

Page 12: ...2 5 10 1 74 5 28 RU 12...

Page 13: ...0 6 0 6 RU 13...

Page 14: ...RU 3 14...

Page 15: ...1 2 3 4 1 2 3 10 20 4 2 5 2 RU 15...

Page 16: ...7 HEATING EQUIPMENT LTD 187000 44 004 2011 020 2011 C RU C RU 66 B 05161 2006 95 2004 108 8 800 333 50 77 09 00 20 00 10 00 18 00 e mail service thermex ru 196105 63 812 313 32 73 www thermex ru RU 16...

Page 17: ...100009 26 8 721 251 28 89 050050 92 421 8 727 233 67 31 220118 66 10 375 173 800 200 58032 246 38 0327 583 200 OOO 73019 1 38 0552 490 129 17 RU...

Page 18: ...Water heater 1 pcs Safety valve of GPtype 1 pcs Anchors for fastening 2 pcs for each securing bar Drainage pipe 1 pcs Operation manual 1 pcs Packaging 1 pcs Application Water heater hereinafter EWH is...

Page 19: ...mal protection is not a malfunction Return of water heater to operating condition is made by pressing thermal switch rod located under EWH protective cover fig 3 Relief valve performs functions of ret...

Page 20: ...lution ensuring junction tightness with any sealing material flax FUM tape etc During water heater operation water may leak out of the exhaust outlet pipe of the safety valve to relieve excessive pres...

Page 21: ...2 Thermo Thermo Slim 1 5 kW 1 kW Both keys correspond to power 2 5 kW You can select heat level basing on needs in volume of hot water or depending on the season In the course of EWH operation user ca...

Page 22: ...assemble fill EWH with water and power on When conducting EWH maintenance by forces of special organization the appropriate mark shall be made in the warranty card When replacing the magnesium anode i...

Page 23: ...s EWH shall be disconnected from the mains water supply shall be cut off Apply to a Service center Thermal switch tripped or not on Powered EWH does not heat water No backlights of indicator lamps Dis...

Page 24: ...shop stamp the warranty period is calculated from the date of EWH manufacture Claims within the warranty period are accepted only on presentation of the warranty card with marks of the seller and the...

Page 25: ...accordance with the rules and regulations of the country where the water heater is operated Manufacturer information Manufacturer HEATING EQUIPMENTLTD 44 Moskovskoe Shosse Tosno Leningrad Region 18700...

Page 26: ...UA 0 05 0 6 230 B 50 2 5 1 2 IPX4 3 40 18 74 5 i i min max i i i i i i i i i Thermex Thermo 80 150 Thermo Slim 30 50 i 1 i GP 1 i 2 i 1 i i 1 1 i i i i i i i i i i i i i 26...

Page 27: ...UA i i 7 8 9 74 5 C 10 93 5 3 11 1 27...

Page 28: ...Thermo 80 150 Thermo Slim 30 50 2 4 i i i 0 5 i i i 200 17 21 3 5 4 28 UA...

Page 29: ...18 17 1 100 24 25 22 23 5 I 4 11 1 i Power I 1 i Power II 2 Thermo Thermo Slim 1 5 1 29 UA...

Page 30: ...2 5 i 10 1 74 5 28 i 30 UA...

Page 31: ...i 0 6 0 6 i 31 UA...

Page 32: ...i i i i i 3 i i i i i i i i i i i i i 32 UA...

Page 33: ...1 2 3 4 1 2 3 10 20 4 2 i 5 2 i i i i 33 UA...

Page 34: ...i i 7 HEATING EQUIPMENT LTD 187000 44 004 2011 020 2011 RU C UA 66 B 05161 2006 95 2004 108 8 800 333 50 77 09 00 20 00 10 00 18 00 e mail service thermex ru 196105 63 812 313 32 73 www thermex ru 34...

Page 35: ...58032 246 38 0327 583 200 OOO 73019 1 38 0552 490 129 0 800 500 610 35 UA...

Page 36: ...KZ 0 05 0 6 230 B 50 2 5 1 2 IPX4 3 40 18 74 5 min max i i i i i i i i i i Thermex 80 150 Thermo 30 50 ThermoSlim 1 GP 1 2 1 1 1 i i i i i i i i i i i i i i i i i...

Page 37: ...KZ i i i i i i i i i i i i i i i i i i 7 8 9 74 5 C 10 93 5 3 11 1 i i...

Page 38: ...i Thermo 80 150 Thermo Slim 30 50 i 2 4 i i i i i i i i i i I i i i i i i i i 0 5 i i i i i i i i i i i i i i i i i i i i i 200 i i 17 21 3 5 4 i i i i i i 38 KZ...

Page 39: ...18 17 i i 1 100 24 25 22 23 5 I 4 11 1 Power I 1 Power II 2 Thermo Thermo Slim 1 5 1 39 KZ...

Page 40: ...2 5 10 1 74 5 28 40 KZ...

Page 41: ...0 6 0 6 41 KZ...

Page 42: ...3 i 42 KZ...

Page 43: ...i 1 2 3 4 1 2 3 10 20 4 i i i i 2 i i i i i i i 5 i i i i i 2 i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i 43 KZ...

Page 44: ...i i i i i i i i i i i i i i i i i i i 7 HEATING EQUIPMENT LTD 187000 44 004 2011 020 2011 RU C RU 66 B 05161 2006 95 2004 108 8 800 333 50 77 09 00 20 00 10 00 18 00 e mail service thermex ru 196105...

Page 45: ...45 100009 26 8 721 251 28 89 050050 92 421 8 727 233 67 31 KZ...

Page 46: ...tak m Su s t c s 1 adet GPtipi emniyet valf 1 adet apa ba lant elemanlar her ba lant tas i in 2 er adet Drenaj borusu 1adet Kullan m k lavuzu 1 adet Ambalaj 1 adet Kullan m amac Elektrikli su s t c s...

Page 47: ...n ayarlanmas termoreg lat r kolu yard m ile ger ekle tirilmektedir 10 ve bu kol su s t c s n n koruma kapa nda bulunmaktad r Termostat n da s anahtar bulunmaktad r elektrikli su s t c s n n a r s nmad...

Page 48: ...ni nlemek i in elektrikli su s t c s n n montaj n n su yal t ml zemine sahip ve kanalizasyon drenaj olan mekanda yap lmas gerekir ve hi bir ekilde elektrikli su s t c s alt na sudan etkilenen nesneler...

Page 49: ...so uk su vanas n 22 elektrikli su s t c s ndan kan s cak su vanas n 23 ve musluktaki s cak su vanas n a n Elektrikli su s t c s tam doldu unda musluktaki vanadan kesintisiz bas n l su akacakt r Muslu...

Page 50: ...k ml l kleri i erisinde de ildir E er boru eklinde elektrikli s t c da kire lenme olu tuysa o zaman kire s k c ler ile veya mekanik yol ile s k lebilir Elektrikli su s t c s ndan keltilerin temizlenm...

Page 51: ...n n aras na takmak yasakt r Elektrikli su s t c s n su hatt na emniyet valfs z ba lant s n yapmak Elektrikli su s t c s ndan g kayna al r durumda iken suyun d k lmesi retici taraf ndan nerilmeyen yede...

Page 52: ...ar kolunun s cakl n azalt lmas y n ne evrilmesi Termostat borusu kire ile kaplanm t r Elektrikli su s t c s ndan s k lebilir flan n kar lmas ve borunun dikkatlice kire ten temizlenmesi Suyun s nma s r...

Page 53: ...ar zas say lmaz ve elektrikli su s t c s n n de i tirilmesini gerektirmez Kurulum ve ba lant kurallar na uyulmas sorumlulu u m teriye kendisinin yapmas durumunda ya da ba lant y ger ekle tiren montaj...

Page 54: ...olarak ger ekle tirilmelidir retici Bilgileri retici HEATING EQUIPMENT LTD Teplovoye Oborudovaniye Ltd ti Rusya 187000 Leningradskaya vilayeti Tosno ehri Moskovskoye ose No 44 T m modeller zorunlu se...

Page 55: ...55...

Page 56: ...e Sat l k tarih Dealer Firma satanlar Service center indicated by dealer Sat c taraf ndan belirlenen servis merkezi Warranty certificates Garanti kartlar Note of sale Mark sat Stamp of dealer Sat c fi...

Page 57: ...tarih 4 Dealer Firma satanlar 5 Stamp of dealer Sat c firma ka esi 6 Filled in by dealer Doldurulur bir firma taraf ndan sat c 1 Model 2 2 Serial No 3 Date of sale 4 Dealer 6 Filled in by dealer 1 Mo...

Page 58: ...Executed work 6 Stamp of service center 5 Specialist name 7 Filled in by service center 1 Date of acceptance 2 2 Issue date 3 Defect 4 Executed work 6 Stamp of service center 5 Specialist name 7 Fill...

Page 59: ......

Page 60: ......

Reviews: