DOC NO. 81078
Page 14 of 18
Rev D 3/06 GM
OneTouch Or Elite Control Installation Instructions
Warning: Power to the generator must be off prior to connecting any control.
1. The
OneTouch
digital control (shown in Figure 7) can be located inside or outside the enclosure.
2. The
Elite
control (shown in Figure 8) MUST be located
INSIDE
the enclosure.
3. Position the control 4 to 6 feet from the floor. Drill a 1-1/16” diameter hole into the wall.
M
M
COAT THE BACK COMPLETELY
WITH SUPPLIED WATERPROOF
SILICONE TO COMPLETELY
SEAL THE CONTROL TO THE
WALL AND NOT ALLOW
MOISTURE BEHIND IT
1-1/16“ DRILL HOLE IN WALL
FOR CONTROL CABLE
50 FT. CONTROL CABLE
FROM STEAM GENERATOR
COUPLER
2.15
4.00
ONETOUCH CONTROL
Figure 7
4. Bring the control cable(s) from the generator through the 1-1/16” diameter hole. Plug the modular
connector of the control into one end of the coupler. Plug the control cable(s) from the generator into
the other end of the coupler.
Route the cable so that the coupler is located ABOVE the hole in
the wall. DO NOT pinch, nail, staple, wedge etc. the cable. DO NOT wrap the cable around
steam line or otherwise route it in such a manner that the hot steam line could melt the cable.
Any damage to the control cable will result in the control not working properly
.
5. For OneTouch/Elite combination connect supplied phone jack splitter to the steam generator, refer
back to Figure 1.
6. Carefully connect the other end of the control cable to the generator BEFORE turning power on to the
generator.
7. Turn on both water and power to the generator.
8. Test the touch pad to ensure it is properly connected. If any technical problems arise, call toll-free
800-776-0711.
CAUTION
Do not use harsh or
abrasive cleaning
chemicals when cleaning
your control.