Electrical Installation
Note: All electrical wiring must be done per National/Local Electrical Codes.
** ThermaSol requires that a licensed electrician perform all electrical work. **
Note: USE COPPER WIRE ONLY.
Wire sizes recommended by NEC (2002 Version). Minimum wire temperature rating 90
°
C. Type THHN.
Generator
Model
Phase
Wire
Gauge
Breaker
Size
Factory Sized
Cu Ft MAX
AMP draw @
240-VAC
K
W
SS-Acrylic 1
10
20
Acrylic Insert
17 3.5
SS-84 1 10 30
84
28 6.0
SS-140 1 8 40
140
37 8.0
SS-240 1 8 50
240
46 10
SS-395 1 6 60
395
55 12
SS-600 1 4 80
500
69 15
Electrical Questions? 800-776-0711 for Technical Support
Warning: Each generator should be wired to their own separate breaker.
1.
Turn off all electricity to the working area at the main breaker panel!
2.
Connect 240-VAC electrical lines to wires labeled 1 & 2 located in the electrical box on
generator, (refer to Figure 6)
.
Figure 6
Wiring diagram