12
STOVE CONTROL PANEL ELECTRICAL SCHEME
TSP = Safety Thermostat
DEP = Air Pressure Switch
F
= Flue Fan
S
= Air Exchanger Fan
C
= Auger
WARNING
•
Before doing any work on the stove related with electricity, ensure that the power
supply cable is disconnected from the network electricity.
•
Sensor wires, sensors and keyboard wires must be mounted so that they cannot be
accessed without disassembling the combustion device.
•
Earth connection must be connected to the controller and to the metal part of the
combustion device.
•
Some of the wires carry dangerous voltages. Disconnect the controller from the
mains power supply prior to any service or mounting operation.
•
Do not exchange high voltage and low voltage connectors during mounting of the
controller.