Pellet Type Optimization and Chimney Type Optimization
WARNING
The following section is reserved for professional technicians with specific knowledge
concerning the product. Random changes in the settings could cause severe damage to the
stove, people and the environment. For this, producer assumes no responsibility.
To get to the Technical Menu, enter the main menu by pressing the P1 key for 2 seconds.
Move up and down using P1 and P2 until you see M8 “Technical Settings” and press P3 to
enter.
Next, press P1 or P2 (press and hold to scroll fast) to enter the access key A9.
Press P3 to confirm the access key and to access the submenu, where you can configure the
various parameters of the stove. The table below shows the submenu.
Menu
Display
M8-1
Settings Factory
M8-2
Set general
M8-3
Type pellet
M8-4
Type chimney
M8-5
Data bank
M8-6
Test outputs
M8-7
Reset part time
M8-8
Reset alarm
M8-9
Counter memories
M8-A
Escape
Within the submenus, by pressing P3 repeatedly you can scroll through all the configuration
parameters. To modify a parameter, press P1 (to decrease) or P2 (to increase). Confirm by
pressing P3. The system will memorize the value entered and the display will show the next
parameter. After last parameter, you can exit the menu by pressing P3 again.
Pellet Type Optimization:
This optimization has 2 steps:
First, the preload time must be optimized. From M8-2, General Setting menu, you can adjust
the preload time with Pr40 parameter. Pellet level on burning pot after preload must be close
to burning pots ignition hole upper level. Since the problem is over loading, pellet loading
time must be decreased. Please note the original value and the adjusted value.