Manual No. 0-5164
3-11 INSTALLATION
ULTRA-CUT 400
CAUTION
No other connections should be made at the ground rod being tested.
This test assumes the 115 or 230 VAC source neutral is connected to the utility earth ground.
Art # A-07252
WARNING
Use extreme caution. This
test uses live voltage.
NEUTRAL
Earth Grounded
HOT
On 115V AC Line:
3VAC = 3 ohms
1VAC = 1 ohm
On 230V AC Line:
1.5VAC = 3 ohms
0.5VAC = 1 ohm
Ground Rod
with other
connections removed
100W Incandescent
light bulb*
* Can replace light bulb with
a 100w resistor.
Use 100 ohm for 115VAC.
Use 500 ohm for 230VAC
NEUTRAL
PROBE
VAC
HOT
PROBE
Ground Testing
2. Increasing the ground rod length beyond 20 - 30 ft (6.1 – 9.1 m) does not generally increase the effectiveness
of the ground rod. A larger diameter rod which has more surface area may help. Sometimes keeping the soil
around the ground rod moist by continuously running a small amount of water into it will work. Adding salt to the
soil by soaking it in salt water may also reduce its resistance. You may also try a chemical ground rod devise.
When these methods are used, periodic checking of the ground resistance is required to make sure the ground
is still good.
D. Routing Of Torch Leads
1. To minimize RF interference, position torch leads as far as possible from any CNC components, drive motors,
control cables, or primary power lines. If cables have to pass over torch leads, do so at an angle. Do not run
the plasma control or other control cables in parallel with the torch leads in power tracts.
2. Keep torch leads clean. Dirt and metal particles bleed off energy, which causes difficult starting and increased
chance of RF interference.
Summary of Contents for Ultra-Cut 400
Page 2: ...Blank...
Page 4: ...Blank...
Page 6: ...Blank...
Page 10: ...This page intentionally blank...
Page 11: ...Insert Table of Con tents tab here Discard this sheet...
Page 12: ...This page intentionally blank...
Page 16: ...TABLE OF CONTENTS This Page Intentionally Blank...
Page 24: ...ULTRA CUT 400 GENERAL INFORMATION 1 8 Manual 0 5164 This Page Intentionally Blank...
Page 26: ...ULTRA CUT 400 GENERAL INFORMATION 1 10 Manual 0 5164...
Page 36: ...SPECIFICATIONS 2 10 Manual No 0 5164 ULTRA CUT 400 This Page Intentionally Blank...
Page 37: ...Manual No 0 5164 2 11 SPECIFICATIONS ULTRA CUT 400 Insert Sec 3 tab here discard this sheet...
Page 38: ......
Page 86: ...INSTALLATION 3 48 Manual No 0 5164 ULTRA CUT 400 This Page Intentionally Blank...
Page 88: ...Blank...
Page 104: ...OPERATION 4 16 Manual No 0 5164 ULTRA CUT 400 This page intentionally blank...
Page 106: ...This page intentionally blank...
Page 110: ...MAINTENANCE 5 4 Manual 0 5164 ULTRA CUT 400 This Page Intentionally Blank...
Page 111: ...Manual No 0 5164 5 5 MAINTENANCE ULTRA CUT 400 Insert Sec 6 tab here Discard this sheet...
Page 112: ...MAINTENANCE 5 6 Manual 0 5164 ULTRA CUT 400 This page is blank intentionally...
Page 139: ...Insert Sec 7 tab here Discard this sheet...
Page 140: ...Blank...
Page 148: ......
Page 158: ...APPENDIX A 10 Manual 0 5164 ULTRA CUT 400 This Page Intentionally Blank...
Page 163: ...Manual 0 5164 A 15 APPENDIX ULTRA CUT 400...
Page 177: ...This Page Intentionally Blank...