9.03 Power Source Problems
Description
Possible Cause
Remedy
1 The welding arc
cannot be
established
A
B
The Primary supply voltage
has not been switched ON.
The Welding Power Source
switch is switched OFF.
A
B
Switch ON the Primary supply
voltage.
Switch ON the Welding Power
Source.
C Loose connections internally. C Have an Accredited Thermal
Arc Service Agent repair the
connection.
2 Maximum output
welding current can
not be achieved
with nominal
Mains supply
voltage.
Defective control circuit
Have an Accredited Thermal
Arc Service Agent inspect then
repair the welder.
3 Welding current
reduces when
welding
Poor work lead connection to
the work piece.
Ensure that the work lead has a
positive electrical connection
to the work piece.
4 No gas flow when
the torch trigger
switch is
depressed.
A
B
Gas hose is cut.
Gas passage contains
impurities.
A
B
Replace gas hose.
Disconnect gas hose from the
rear of Power Source then
raise gas pressure and blow
out impurities.
C Gas regulator turned off.
C Turn gas regulator on.
D Torch trigger switch lead is
disconnected or switch/cable
is faulty.
D Reconnect lead or repair faulty
switch/cable.
Summary of Contents for 250TS DC CC