CM Oven Service Manual
Lit. No. 94-30-006B
Page 39
7.
Remove the four bracket screws from the
lower crossflow blower assembly and re-
move the assembly from the oven.
8.
Disconnect the two motor wires (BU-74
& WH-75) and remove them from the wire
wrap.
12. Bend the flange covering the hidden bake
element down as necessary to remove the
element.
13. Disconnect the two orange wires (22 & 29)
from the bake element terminals.
14. Remove the four screws from the mount-
ing and element brackets (2 each).
10. Remove the plastic grommet from the
blower mounting plate hole and remove
the grommet from the wiring.
11. Bend the blower mounting plate down 90˚
along the perforated edge.
9.
Remove the nine screws from the blower
mounting plate.
Crossflow Blower
Assembly
Screws
(2 of 4)
Motor Connectors
15. Position the wiring to the side and pull
the bake element and mounting bracket
out of the oven.
Bend Plate Down 90˚
Bend Flange Down To Access Bake Element
Blower Mounting Plate
Plastic Grommet Screw (1 of 9)
Mounting Bracket Element Bracket
Mtg. Bracket Element Bracket
Screw (1 of 2)
Screws
Wiring
Pull Bake Element &
Bracket Out