6 Service Parts: HI-E Dry 100 Dehumidifier

ITEM   PART NO.  

QTY.  

DESCRIPTION

4022254 

Accumulator

4021475 

Air Filter, Pleated, 2” x 16” x 20”

4021468 

Air Filter, Foam Element

4026930 

Blower

4028233 

Capillary Tubes

4029168 

Compressor 

4029169 

Compressor Overload

4029845 

Compressor Run Capacitor, 45 MFD

4024965 

Condensate Pump 

10 

4028226 

Condenser Coil

11 

4023495 

Cord & Wire Harness

12 

4021470 

Defrost Thermostat

 

4021648 

Defrost Thermostat Mounting Clip for item 12

13 

4028225 

Evaporator Coil

14 

4029510 

Filter/Drier

15 

4017152 

Hose, Drain, .38” OD x 20’ long

16 

4021469 

Humidity Controller

17 

4021495 

Knob, Humidity Controller

18 

4025560 

Switch, SPDT, for Fan

19 

4021471 

Wheel, 2”, Plastic

20 

4023609 

Wiring Diagram (on Cover) (not shown)

21 

4021453 

Optional Ducting Kit (for Inlet & Outlet) (not shown)

22 

4020623 

Optional Outlet Collar (for Ducting Outlet only) (not shown)

23 

4021823 

Defrost Timer (not shown)

24 

1970010 

Relay (not shown)

8

www.thermastor.com • [email protected]

Toll-Free 1-800-533-7533

www.sylvane.com 1-800-934-9194

Summary of Contents for HI-E DRY 100

Page 1: ...Free 1 800 533 7533 www thermastor com sales thermastor com Table of Contents 1 Specifications 1 2 Installation 1 2 1 Location 1 2 1A In humid area no ducting 1 2 1B In humid area duct inlet and or o...

Page 2: ...adequate air flow path must exist between the two rooms for this method to work well An additional humidity control may need to be mounted in the humid area and wired to the HI E Dry to accurately ma...

Page 3: ...y whether the unit is dehumidifying or not This function is desirable if the unit is used for air circulation or fresh air ventilation 3 3 Defrost Control Adjustment When the HI E Dry 100 is used in a...

Page 4: ...t pressure and temperature to drop It next enters the evaporator coil where it absorbs heat from the incoming air and evaporates The evaporator operates in a flooded condition which means that it shou...

Page 5: ...wer motor required for removal clearance 7 Remove the nuts bolts holding the blower outlet flange to the cabinet end and remove the blower 8 Reassembling with the new blower is the above procedure rev...

Page 6: ...while the compressor was not rotating Contaminants are therefore largely confined to the compressor housing A single installation of liquid and suction line filter driers will probably clean up the s...

Page 7: ...eplace the condensate pump 1 Unplug the unit remove the front cover 2 Disconnect the 2 hoses from the pump 3 Cut the pump lead wires near the old pump 4 Remove the 2 nuts from the unit side that hold...

Page 8: ...mostat 4021648 1 Defrost Thermostat Mounting Clip for item 12 13 4028225 1 Evaporator Coil 14 4029510 1 Filter Drier 15 4017152 1 Hose Drain 38 OD x 20 long 16 4021469 1 Humidity Controller 17 4021495...

Page 9: ...ions To prevent damaging the foam filter place it grid side up on top of the pleated filter and slide them both into the filter slot 9 www thermastor com sales thermastor com Toll Free 1 800 533 7533...

Page 10: ...10 www thermastor com sales thermastor com Toll Free 1 800 533 7533 www sylvane com 1 800 934 9194...

Page 11: ...use lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor s reasonable control Lim...

Reviews: