1 Specifications
Model:
HI-E DRY 100 Dehumidifier
Electrical
: 110-120 Vac, 6.6 Amps, grounded
Capacity:
100 pints/day @ 80°F, 60% RH
Operating Temp. Range:
33°F min., 110°F max.
Air Flow:
275 CFM
Refrigerant Charge:
1 lbs., 7 oz. R410a
Optional Duct Connections:
8” round inlet & outlet
Size (w/o duct collars):
20” long x 17” wide x 36” high
Weight:
110 lbs.
2 Installation
2.1 Location
The HI-E Dry can be installed in a variety of locations
to meet the owner’s needs as listed below. In all cases
keep the following cautions in mind:
• It is designed to be installed
INDOORS ONLY.
• If used near a pool or spa, be certain there is
NO
chance the unit could roll into the water or be
splashed and that it is plugged into a
GROUND FAULT
INTERRUPTER.
•
DO NOT
use the HI-E Dry as a bench or table.
• Avoid discharging the air directly at people, especially
in pool areas.
2.1A In Humid Area, No Ducting
The simplest installation is to place the HI-E Dry in the
humid area with no ducting. The air inlet on top & outlet
on the side must be at least 1’ from walls and other
obstructions to air flow.
TS-598 11/09
P.O. Box 8680, Madison, WI 53708
Phone 608-222-5301 • Toll-Free 1-800-533-7533
www.thermastor.com • [email protected]
Table of Contents
1. Specifications
........................................................1
2. Installation
............................................................1
2.1 Location .........................................................1
2.1A In humid area, no ducting ..........................1
2.1B In humid area, duct inlet and/or outlet .......2
2.1C In remote area, duct inlet & outlet .............2
2.1D In remote area, duct outlet only .................2
2.1E In remote area, duct inlet only ...................2
2.2 Electrical Requirements ...................................2
2.3 Condensate Removal ...................................... 2
2.4 Ducting .......................................................... 2
2.4A Optional Ducting ..................................... 2
2.4B Ducting for Dehumidification .................... 2
2.4C Ducting for Fresh Air .................................2
3. Operation
............................................................3
3.1 Humidity Control Adjustment ............................3
3.2 Fan Switch ..................................................... 3
3.3 Defrost Control Adjustment ..............................3
4. Maintenance
........................................................4
4.1 Air Filter .........................................................4
5. Service
.................................................................4
5.1 Warranty. ........................................................4
5.2 Technical description .......................................4
5.3 Troubleshooting ...............................................4
5.4 Refrigerant Charging ........................................5
5.5 Blower Replacement ....................................... 5
5.6 Compressor/Capacitor Replacement ................5
5.6A Checking Compressor Motor Circuits .........5
5.6B Replacing a Burned Out Compressor .........6
5.6C Replacing a Compressor- Non-Burn Out ......6
5.7 Relay ..............................................................6
5.8 Humidity Control..............................................7
5.9 Defrost Thermostat .........................................7
5.10 Condensate Pump .........................................7
6. Wiring Diagrams
....................................................7
7. Service Parts List
..................................................8
8.
Filter Installation Instructions
..................................9
9. Warranty
.............................................................11
Serial No. __________________________________
Purchase Date ______________________________
Dealer’s Name ______________________________
Specifications subject to change without notice.
HI-E DRY 100 High Efficiency Dehumidifier
Installation, Operation & Service Instructions
HIGH EFFICIENCY DEHUMIDIFICATION
1
Toll-Free 1-800-533-7533
When unpacking, make
sure to remove corrugated,
protective cardboard from
top of unit.
www.sylvane.com 1-800-934-9194