background image

 Page 9 of  15 

 

1.25hp and 1.75hp TVS  VARIABLE 3 SPEED OPERATION 

 

The TVS Pro Variable Speed Pumps has 3 speed settings…. 
 

1.

 

Eco (Energy Saving) 

 

This should be used for everyday water filtration 

 

The pump should be operated for approximately 8 hours per day depending on the 
surrounding climate, bather loads, pool volume and length of pipework. 

 

In some cases when your pool has areas where water is not turning over, increase the 
speed setting 

 

This setting is 

not

 recommended to be used with a suction cleaner but may work. 

2.

 

Med 

 

This should be used for gentle spa jet action and the majority of suction cleaners when 
connected to a skimmer box 

3.

 

High 

 

This should be used for backwashing, manual vacuuming of the pool, operating gentle or 
soft spa jets and/or water features. 
 

PLEASE NOTE 

 

The TVS Pro will always run at “high” speed for 3 minutes upon start up or a filter 
cycle.  This assists with priming of the pump and pipe work. 

 

After the initial 3 minutes the TVS Pro will revert back to the previous selected speed 

it was set at before it was turned off. 

 

Priming function can be disable, however, this is not recommended 

 

 

CHANGING PRIME ON/OFF, PRIME DURATION AND PRIME SPEED 

 

Turning Prime On / Off 

o

 

Press the stop button 3 times simultaneously 

o

 

Screen should read “P off” 

o

 

Do this again to turn it on, “P on” 

o

 

Disabling Prime function is not recommended for standard operation use 

 

Changing Prime Duration 

o

 

Hold Off button for 10sec 

o

 

Screen with display P 3  --  Depicting 3 Minutes 

 

This can be increase up to 120 minutes 

 

Press set to save 3 times 

 

Changing Prime Speed 

o

 

Hold Off button for 10sec 

o

 

Screen with display P 3  --  Depicting 3 Minutes 

o

 

Change Prime Duration if required (See above) 

 

Press Set --  P 3 

 

Screen will display 2850 (Highest possible speed) 

 

Increase or decrease as desired by using up and down arrows 

 

Press set to save 2 times 

 

Summary of Contents for TVS PRO

Page 1: ...Page 1 of 15 TVS PRO VARIABLE 3 SPEED POOL SPA PUMP INSTALLATION AND OPERATION MANUAL Theralux 12 Gatwood Close Padstow NSW 2211 Ph 1300 131 788 www theralux com au...

Page 2: ...he main drain cover Ensure the skimmer baskets and the pump hair and lint pots are free of leaves and debris at regularly Remove obstructions and combustibles from around the pump motor Make sure all...

Page 3: ...commends that all installations are fitted with earth leakage or residual current protection devices Ensure that an electrical isolation switch is located with easy access so that the pump can be swit...

Page 4: ...from overheating Every THERALUX pool and spa pump is thoroughly water tested against flow pressure voltage current and mechanical performance parameters THERALUX S advanced pump technology provides re...

Page 5: ...er Enclosures should be ventilated to allow a free flow of air for the fan cooled motor Power Connection THERALUX pool and spa pumps are suitable for connection to a nominal 240 volt 50Hz power supply...

Page 6: ...on on the swimming pool filter at the filter valve For pump installations above water level it generally requires a check valve in the suction line Do not use type P green plumber s glue on the barrel...

Page 7: ...place the lid ensuring that it seals on the large o ring 2 Connect to the power supply and switch on 3 Allow the pump to run so that any air trapped in the pipe work and pump may be expelled 4 If prim...

Page 8: ...Page 8 of 15 Factory Setting Speeds Star Ratings 1 25hp TVS PRO Low 1600 Medium 2400 High 2850 1 75hp TVS PRO Low 1450 Medium 2400 High 2850 Adjustable Speed Mode...

Page 9: ...h speed for 3 minutes upon start up or a filter cycle This assists with priming of the pump and pipe work After the initial 3 minutes the TVS Pro will revert back to the previous selected speed it was...

Page 10: ...into pump from controller When connect screen should display It is now in slave mode WHEN USING WITH THERALUX ECOMMANDER Priming function must be disabled prior to connecting communication plug to mo...

Page 11: ...be inspected frequently through the transparent lid and emptied when a build up of rubbish is evident Follow the directions below 1 Switch off pump 2 Unscrew the hair and lint pot strainer basket lid...

Page 12: ...er flow is reduced the following condition may apply 1 The filter requires backwashing or it is blocked 2 Disconnect the suction cleaner 3 Check the skimmer box for blockage 4 The pump is not primed i...

Page 13: ...Verify the proper impeller has been applied net 1 0Hp max Turn the power off at the timer breaker and allow motor to remain off for at least 15 minutes before reapplying power 4 Er04 Over current trip...

Page 14: ...damage caused by running the pump off an extension cord damage caused by foreign material blocking the impeller pebbles organic matter toys etc or if the pool pump is used for any other purpose other...

Page 15: ...ALUX dealer THERALUX Customer Service Centre and from the relevant product Installation and Operating Instructions This data sheet must be read in conjunction with the relevant product Installation an...