Read these instructions before operating the pool and spa pump. 

 

Please pass these instructions on to the owner of this equipment. 

 

MODEL: TVS Pro 1.25hp and 1.75hp 

 

DANGER - HAZARDOUS SUCTION

 

Do not block water entry into filtration system with any part of your body as the suction can trap hair 
or body parts, causing severe injury or death. Do not block suction. Turn off pump immediately if 
someone becomes trapped. 

 

Careful Reminder 

 

This appliance is not intended for use by persons (including children) or person/s with reduced 
physical, sensory or mental incapability’s, or lack of experience and knowledge, unless they have 
supervision or instruction concerning use of the appliance by a person responsible for their safety. 

 

Please check your pump basket, skimmer and entire pool system regularly to maximize the life of 
your pool equipment & personal safety. Turn pump off first before checking baskets. 

 

Make sure that all pressure gauges installed are in working condition and the operating pressure is 
within limits as specified on the product. 

 

Make sure that each suction inlet, and main drain has a cover that is securely attached and in safe 
working condition to meet with all current legislation. 

 

Make sure that all skimmer covers (deck lids) are securely attached and in safe working condition. 

These should be replaced every 3 to 4 years. 

 

Remove any obstructions or debris from the main drain cover. 

 

Ensure the skimmer baskets and the pump hair and lint pots are free of leaves and debris at regularly. 

 

Remove obstructions and combustibles from around the pump motor. 

 

Make sure all wiring connections are clean and that all wiring and electrical equipment is in good 
condition. Damaged wiring must be repaired or replaced by a qualified electrician as soon as damage 
is discovered. 

 

Do not add chemicals directly to the pool skimmer. Adding undiluted chemicals may damage pump, 

heater, etc and void warranty. 

 

Check water balance and sanitizer levels at your local pool shop. 

 

WARNING!

  

 

CHILDREN SHOULD BE SUPERVISED AT ALL TIMES TO ENSURE THAT DO NOT PLAY WITH THE PUMP 
OR ANY POOL ASSOCIATED ELECTRICAL DEVICE 

 

Pump suction is hazardous and can cause entrapment, drowning or disembowel bathers.

 

 

Do not block or cover any pool/spa suction.

 

 

Do not use or operate swimming pools, spas or spa baths if a suction cover is broken, missing or 
loose. 

 

 

Suction covers and inlets must be installed as per Australian Standards guideline and provided for 
every pump to avoid suction entrapment.

 

 

CAUTION!

 

 

In the interest of safety, we advise that all brands and types of pool pumps must be installed in 
accordance with AS3000 wiring rules or equivalent

 

 

If the pump and filter are located below pool water level, it is necessary to fit isolating valves in the 

pipe between the pump and the skimmer box and in the return pipe from the filter to the pool.

 

 

The fittings on this product are constructed of ABS. Some PVC jointing compounds are incompatible 
with ABS. Check compound suitability before use.

 

Summary of Contents for TVS PRO

Page 1: ...Page 1 of 15 TVS PRO VARIABLE 3 SPEED POOL SPA PUMP INSTALLATION AND OPERATION MANUAL Theralux 12 Gatwood Close Padstow NSW 2211 Ph 1300 131 788 www theralux com au...

Page 2: ...he main drain cover Ensure the skimmer baskets and the pump hair and lint pots are free of leaves and debris at regularly Remove obstructions and combustibles from around the pump motor Make sure all...

Page 3: ...commends that all installations are fitted with earth leakage or residual current protection devices Ensure that an electrical isolation switch is located with easy access so that the pump can be swit...

Page 4: ...from overheating Every THERALUX pool and spa pump is thoroughly water tested against flow pressure voltage current and mechanical performance parameters THERALUX S advanced pump technology provides re...

Page 5: ...er Enclosures should be ventilated to allow a free flow of air for the fan cooled motor Power Connection THERALUX pool and spa pumps are suitable for connection to a nominal 240 volt 50Hz power supply...

Page 6: ...on on the swimming pool filter at the filter valve For pump installations above water level it generally requires a check valve in the suction line Do not use type P green plumber s glue on the barrel...

Page 7: ...place the lid ensuring that it seals on the large o ring 2 Connect to the power supply and switch on 3 Allow the pump to run so that any air trapped in the pipe work and pump may be expelled 4 If prim...

Page 8: ...Page 8 of 15 Factory Setting Speeds Star Ratings 1 25hp TVS PRO Low 1600 Medium 2400 High 2850 1 75hp TVS PRO Low 1450 Medium 2400 High 2850 Adjustable Speed Mode...

Page 9: ...h speed for 3 minutes upon start up or a filter cycle This assists with priming of the pump and pipe work After the initial 3 minutes the TVS Pro will revert back to the previous selected speed it was...

Page 10: ...into pump from controller When connect screen should display It is now in slave mode WHEN USING WITH THERALUX ECOMMANDER Priming function must be disabled prior to connecting communication plug to mo...

Page 11: ...be inspected frequently through the transparent lid and emptied when a build up of rubbish is evident Follow the directions below 1 Switch off pump 2 Unscrew the hair and lint pot strainer basket lid...

Page 12: ...er flow is reduced the following condition may apply 1 The filter requires backwashing or it is blocked 2 Disconnect the suction cleaner 3 Check the skimmer box for blockage 4 The pump is not primed i...

Page 13: ...Verify the proper impeller has been applied net 1 0Hp max Turn the power off at the timer breaker and allow motor to remain off for at least 15 minutes before reapplying power 4 Er04 Over current trip...

Page 14: ...damage caused by running the pump off an extension cord damage caused by foreign material blocking the impeller pebbles organic matter toys etc or if the pool pump is used for any other purpose other...

Page 15: ...ALUX dealer THERALUX Customer Service Centre and from the relevant product Installation and Operating Instructions This data sheet must be read in conjunction with the relevant product Installation an...

Reviews: