WHEN USING WITH THERALUX / POOL+ MANAGER CONTROLLER WITH RS485 COMMUNICATION
Press and hold OFF button for 10secs
Screen will display P 3 -- Press SET
Screen will display 2850 -- Press SET
Screen will display -- Mod Off
o
Press Up or DOWN arrows
o
Screen will display Mod On - Press SET
Plug cable into pump from controller
When connect screen should display “----” It is now in slave mode
WHEN USING WITH THERALUX ECOMMANDER
Priming function must be disabled prior to connecting communication plug to motor
o
Press the stop button 3 times simultaneously
o
Screen should read “P off”
o
Do this again to turn it on, “P on”
Set speeds prior to connecting communication plug to motor
o
Adjust eco and solar heat demand speed, then save prior to connecting comms
cable
Plug comms cable into pump from controller