Theralux TVS PRO Installation And Operation Manual Download Page 13

 Page 13 of  15 

 

Barrel unions need to be hand tightened. No sealant, glues or silicones are required.

 

 

When making any enquiries about your 

THERALUX

 pool and spa pump be certain to quote the 

model number from the nameplate located on motor.

 

NOTES:  (cont) 

 

Never run pump dry. Running the pump with no water may damage the mechanical seals, 
causing leakage and flooding. Dry running damage and associated damage is not covered under 

warranty.

 

 

Failure to undertake regular maintenance may cause damage not covered by warranty.

 

 

The pump is not intended for use by young children or infirm persons without supervision. 

Ensure that young children are supervised at all times to ensure that they do not play with the 
pump.

 

 
FAULT CODES 

 

Blinks/ 

Display 

Fault 

Software Cause 

Action 

1/

 Er01

  Micro 

controller 

failure 

Micro controller is 
continually rebooting. 

No action can be taken to resolve issue.  Return 
motor for warranty. 

2/

 Er02

  Under 

voltage 

The line voltage has 
dropped below 180 
volts AC running. 

- The controller will reboot after voltage comes 
above 209 volts AC for at least 6 seconds. 
- Reduce distance between motor/pump and breaker. 

- Turn off any other non-critical equipment on the 
same breaker circuit. 

3/

 Er03

  Temperature  Internal electronics 

detected an over 
temperature condition 

(+100C on sensor) 

- Verify the proper impeller has been applied (net 

1.0Hp max) 
- Turn the power off at the timer / breaker and allow 

motor to remain off for at least 15 minutes before 
reapplying power. 

4/

 Er04

  Over current 

trip 

Over current 

protection has tripped.  

- Verify the proper impeller has been applied (net 

1.0Hp max) 
- Inspect all equipment / piping in the system 

connected to the pump 

5/

 Er05

  Over voltage  The line voltage has 

risen above 269 volts 

AC. 

- The controller will reboot after voltage comes below 
254 volts AC for at least 6 seconds. 

6/

 Er06

  Output shaft 

seized 

Motor failed to start. 
Motor was stopped. 

- Manually rotate the shaft via the shaft access  in 
the fan cover 

- Inspect all equipment in-line with the pump for 
obstructions or locked pump parts. 

7/

 Er07

  Self-check 

One or more of the 
self-tests failed either 

at start up or while 
running. 

- Turn the power off at the timer / breaker and allow 
motor to remain off for at least 15 minutes before 

reapplying power. 
- Return motor for warranty if error persists. 

8/

 Er08

  Motor fault  One or more of the 

phases has become 
disconnected. 

- Turn the power off at the timer / breaker and wait 

one minute before opening the topside connection 
enclosure.  Verify phase leads from both the motor 

and control connecting into the terminal block (red, 
yellow, white leads on left-most connections of 

blocks as viewed from the conduit entrance) are 
properly connected and screws on the terminal block 

are tightened sufficiently. 

*** Sequential LED blinks will indicate the fault code. *** 

Summary of Contents for TVS PRO

Page 1: ...Page 1 of 15 TVS PRO VARIABLE 3 SPEED POOL SPA PUMP INSTALLATION AND OPERATION MANUAL Theralux 12 Gatwood Close Padstow NSW 2211 Ph 1300 131 788 www theralux com au...

Page 2: ...he main drain cover Ensure the skimmer baskets and the pump hair and lint pots are free of leaves and debris at regularly Remove obstructions and combustibles from around the pump motor Make sure all...

Page 3: ...commends that all installations are fitted with earth leakage or residual current protection devices Ensure that an electrical isolation switch is located with easy access so that the pump can be swit...

Page 4: ...from overheating Every THERALUX pool and spa pump is thoroughly water tested against flow pressure voltage current and mechanical performance parameters THERALUX S advanced pump technology provides re...

Page 5: ...er Enclosures should be ventilated to allow a free flow of air for the fan cooled motor Power Connection THERALUX pool and spa pumps are suitable for connection to a nominal 240 volt 50Hz power supply...

Page 6: ...on on the swimming pool filter at the filter valve For pump installations above water level it generally requires a check valve in the suction line Do not use type P green plumber s glue on the barrel...

Page 7: ...place the lid ensuring that it seals on the large o ring 2 Connect to the power supply and switch on 3 Allow the pump to run so that any air trapped in the pipe work and pump may be expelled 4 If prim...

Page 8: ...Page 8 of 15 Factory Setting Speeds Star Ratings 1 25hp TVS PRO Low 1600 Medium 2400 High 2850 1 75hp TVS PRO Low 1450 Medium 2400 High 2850 Adjustable Speed Mode...

Page 9: ...h speed for 3 minutes upon start up or a filter cycle This assists with priming of the pump and pipe work After the initial 3 minutes the TVS Pro will revert back to the previous selected speed it was...

Page 10: ...into pump from controller When connect screen should display It is now in slave mode WHEN USING WITH THERALUX ECOMMANDER Priming function must be disabled prior to connecting communication plug to mo...

Page 11: ...be inspected frequently through the transparent lid and emptied when a build up of rubbish is evident Follow the directions below 1 Switch off pump 2 Unscrew the hair and lint pot strainer basket lid...

Page 12: ...er flow is reduced the following condition may apply 1 The filter requires backwashing or it is blocked 2 Disconnect the suction cleaner 3 Check the skimmer box for blockage 4 The pump is not primed i...

Page 13: ...Verify the proper impeller has been applied net 1 0Hp max Turn the power off at the timer breaker and allow motor to remain off for at least 15 minutes before reapplying power 4 Er04 Over current trip...

Page 14: ...damage caused by running the pump off an extension cord damage caused by foreign material blocking the impeller pebbles organic matter toys etc or if the pool pump is used for any other purpose other...

Page 15: ...ALUX dealer THERALUX Customer Service Centre and from the relevant product Installation and Operating Instructions This data sheet must be read in conjunction with the relevant product Installation an...

Reviews: