PMC/XMC Carrier Board Manual
A-8
Themis Computer
Figure A-8.
Press Down on the PMC Interface Standoffs
Figure A-9.
Use Interposer Material if PMC Interface Standoffs Don’t Exist
5. Verify complete seating of the mating connectors by observing that the PMC
Carrier Board is resting against the Baseboard standoff nuts. (The 1/8” gap in
Figure A-7
should be gone.)
6. Apply a
small amount
of Loctite 222 MS (shown in
Figure A-10
) or a similar low-
strength thread locker to the last few threads of all the screws. Refer to
Figure A-11
and
Figure A-12
.
Press down on PMC standoff
nuts, applying approximately
5 pounds of downward force.
If your system doesn’t have
PMC standoff nuts, use an
interposer to press down
on the PMC connectors.