PARLOUR PELLET 3000
PELLET HEATER
9
4FIGURE 5
FIGURE 6
INSTALLATION
Attachment and securing of the exhaust venting
system to the product and to each adjoining
sections: All joints for the connector pipe should be
fastened with three screws. If vented horizontally,
joints should be made gas tight (see Item 9b).
Install vent at clearances specified by the vent
manufacturer.
1.
When deciding on the location of your heater
and vent pipe, try to minimize the alteration and
reframing of structural components of the
building. Vent pipe must be installed so that
access is provided for inspection and cleaning.
2.
Avoid installing heater in high-traffic areas. Keep
children away from heater when in operation.
3.
Outside air required (see Figure 10).
4.
A 3-inch clearance to combustibles must be
maintained for horizontal and vertical
venting
. When passing through ceilings or
walls, you must use a listed wall thimble,
making sure all combustible materials and
insulation products are a minimum of 3 inches
away from the pellet vent pipe. If using the
Pellet Pro pipe, a 1” clearance is required.
5.
A non-combustible hearth pad must be used if
installed on a carpet, wood floor, or other
combustible material (see Figure 5).
6.
Keep front door of appliance thirty-six (36)
inches from combustibles (drapery, furniture).
Summary of Contents for PARLOUR 3000
Page 4: ...PARLOUR PELLET 3000 PELLET HEATER 4 of 31 LABORATORY LISTING LABEL...
Page 20: ...PARLOUR PELLET 3000 PELLET HEATER 20 FIGURE 15 REPLACEMENT PARTS LIST 16...
Page 25: ...PARLOUR PELLET 3000 PELLET HEATER 25 APPENDIX B E I FIREPOT ASSEMBLY...
Page 26: ...PARLOUR PELLET 3000 PELLET HEATER 26 APPENDIX B OUTSIDE AIR HOOK UP...
Page 29: ...PARLOUR PELLET 3000 PELLET HEATER 29 APPENDIX E REPLACEMENT OF IGNITER...