APPENDIX A – WIND WARNING
Additional Venting Problems
Occasionally, the vent configuration can create a
noisy, harmonic condition that will make a noise
similar to the one made by blowing over a bullet
shell or beer bottle. This sound can be eliminated by
closing the air damper located on the bottom front
of the stove under the bottom ring.
Your Thelin Pellet Stove is equipped with a blocked
flue/high temp safety sensor that will shut the stove
off if there is a down draft, blocked flue, or high
temperature condition.
If you install the stove on the side of the house that
is hit by prevailing winds (usually 30 to 40 mph or
greater) there is a chance that the sensor will be
activated and the stove will shut off. The solution to
this problem is to run the pipe up vertically through
the eave and use a high wind cap on the vertical
termination (see diagram).
You are welcome to call if you have any questions
about this potential problem.
Thelin Hearth Products
(800) 949-5048