![THE SHOWER LAB VIEW 23 Manual Download Page 21](http://html1.mh-extra.com/html/the-shower-lab/view-23/view-23_manual_1100496021.webp)
05/2021 V 1.0
VIEW 23
Wet Side
Inside Enclosure
Open Out
Inside Enclosure
Open In
Glass Supports
13/17
Attach the Glass to Glass Bubble “h”
Seal to the Inline Panel.
Check the orientation is correct.
Leave the seal oversized. This will be
trimmed later.
Place the Glass Supports over the
Underframe as shown. With one
person inside the enclosure, position
the Door onto the supports.
Add Spacers to the Glass Supports in
order to level the Door.
With someone inside, carefully replace
the Door onto the Supports.
Check all Panels are level and square
and that the Seals touch fully.
Attach the Glass to Glass Hinges to the
door and tighten.
Use 5mm Packers in gap and evenly
tighten the screws until the gaskets are
just “nipped”.
Tighten all screws to 15.6N.
DO NOT fit the Cover Plates yet.
37
38
39
40