background image

Most Modern Fan Co. products have been in our assortment for several 
years or longer. As we continually work to improve product performance 
and user experience, we occasionally introduce subtle (and sometimes 
dynamic) product changes. These can affect the steps associated with 
assembly and installation of our products depending on when a fan  
was produced.

The instructions posted here are intended to represent our most current 
product versions and configurations and the associated installation 
steps. If your fan or parts of your fan do not appear to match what is 
included here, please contact customer service for guidance and support 
in identifying which version of a fan you may have and provision of the 
associated installation instructions which correspond to that version.

If in doubt, or if you have any questions at all related to assembly, 
installation or operation of your fan, please contact us!

A note about our  

online installation instructions:

 

709 Washington Street, Ashland, OR 97520

tel 888-588-3267, fax 541-482-8418

[email protected]

modernfan.com

Summary of Contents for Cirrus DC

Page 1: ...uct versions and configurations and the associated installation steps If your fan or parts of your fan do not appear to match what is included here please contact customer service for guidance and sup...

Page 2: ...rrus DC Installation Instructions and Owners Manual Customer Service Monday Friday 8am 4pm PST tel 888 588 3267 Safety Instructions and Warnings 2 Fan Installation 4 Control Installation and Wiring 8...

Page 3: ...ble for Fan Support and use mounting screws provided with the outlet box Note Most outlet boxes commonly used for light fixtures are not acceptable for fan support and may need to be replaced Consult...

Page 4: ...l must be grounded using the attached green wire After making wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the out...

Page 5: ...ded A stepladder phillips head screwdriver and a wire stripper blades canopy fan body bottom dome 2nd down rod balancing kit hardware package control s may include 2 or 3 pieces hanging bracket Option...

Page 6: ...set aside for reinstallation c Slightly loosen three set screws where down rod is attached to motor and remove the cotter pin and through pin assembly Set all parts aside for reinstallation d Remove...

Page 7: ...d in the slotted channel in the half ball Carefully insert one blade into a rotor slot Using pan head screws from hardware package to secure blade to rotor Screwdriver and screws pass through oval hol...

Page 8: ...refully pull feed the blue and white pair of wires through the fan body Once connected gently pull on the same wires from above until board is flat against trim ring Position LED board flat on surface...

Page 9: ...colors labels and diagram below If ordered install wall switch into wall box taking note of dip switch settings and related instructions referenced below 7 receiving unit receiving unit switch plate...

Page 10: ...cover of the remote handset and on the left side of the wall control See image below With dimming enabled pressing and holding the LIGHT button will increase or decrease brightness with the minumum a...

Page 11: ...rol with the receiver Begin by turning power off at the wall control at the main switch leg or at the circuit breaker if there is no wall control or on off switch in use Switch the power supply back o...

Page 12: ...of warmer air trapped at the ceiling level The LIGHT button turns the light on and off with each contact If dimming is enabled pressing and holding the light button will achieve continuous dimming cyc...

Page 13: ...Please read all installation instructions carefully After reviewing the following troubleshooting tips if you are unable to solve a problem with the installation or operation of you fan please contact...

Page 14: ...irmly secured Loose parts will often cause vibrational noise or humming Removal and re attachment can sometimes remedy such resonant vibrational noise Fan or light not responding to hand held remote o...

Page 15: ...eterioration or oxidizing effects of salt or other corrosive elements A Damp Location rating is not an assurance of finish durability Preventative measures should be taken dependent on the environment...

Page 16: ...his warranty only covers the replacement or repair of ceiling fan or parts as specified above and does not cover any other costs incurred related to installation labor or equipment or shipping of fan...

Page 17: ...V2019 02 The Modern Fan Company Inc 709 Washington Street Ashland Oregon 97520 tel 888 588 3267 fax 541 482 8418 info modernfan com modernfan com...