Discharge Logic Assembly
A Discharge Logic Assembly is a Basic Logic Assembly without a solenoid valve attached. It can be
used to control the release from the last, discharge zone of a length of CRUZcontrol. Since there is no
solenoid valve, the same Discharge Logic Assembly will work for either NBA™23 or XenoROL
®
applications.
The Discharge Logic Assembly is mounted on the charge end of the conveyor immediately downstream
of the last (discharge) zone of a length of CRUZcontrol accumulation conveyor. It is connected to the
Logic Assembly of the discharge zone as shown. There is no need for a Function Module to be attached
to it. The DLA does not need to be given a release signal. Product blocking that photoelectric sensor
will stop release from the CRUZcontrol discharge zone, until the photoelectric sensor clears again. This
operation can usually be left enabled and ready to function regardless of whether the receiving conveyor
is running or off. There would be no need to interface the CRUZcontrol operation with the receiving
conveyor operation, since the functioning of it is based solely on product movement.
The following hardware listing is for two Discharge Logic Assembly kits consisting of the Discharge Logic
Assembly, a reflector, and mounting brackets. The mounting brackets provide for the mounting of the
Discharge Logic Assembly and reflector either ½ inch or 3 inches above a standard XenoROL side
channel. Since every application is different, there will usually be a need to drill mounting holes for the
brackets.
TGW Systems Part Number
Description
E0006240
Discharge Logic Assembly Kit, ½ inch above rollers scan
height
E0006236
Discharge Logic Assembly Kit, 3 inch above rollers scan
height
CONVEYOR FLOW
DISCHARGE
LOGIC
ASSEMBLY
LOGIC
ASSEMBLY
Receiving Conveyor
(Without CRUZcontrol)
CRUZcontrol
Discharge Zone