background image

 

37

Note:

 

This setting is related to the alarm sound only. Alarms that have been 

set, continue to be registered. Also they are shown on the display as 

well. Only the sound is activated or inactivated by this setting in case of 

an alarm. 

 
Time reception ON/OFF: 

 „DCF“  appears  on  the  text  display  and  the  default  „On“  starts 
flashing. 
 With the + or - button you can deactivate (OFF) or activate (On) 
the DCF time  reception.  

 

12/24-Hour format: 

 „TIMEFORMAT“ appears on the text display and the default „24 h“ 
starts  flashing.  Also  the  current  time  will  be  shown  in  the  display. 
With the +  or -  button  you can select  between 12 hr or 24  hr time 
format.  If  you  select  the  12  hr  time  format,  AM  or  PM  appears  in 
the display additionally.  

 

Temperature unit (°C/ °F): 

„TEMP  UNIT“  appears  on  the  text  display  and  the  default  „°C“ 
starts flashing. With the + or - button  you can select between „°C“ 
or „°F“ as the temperature unit. 

 

Manual time setting: 

 „TIME  SET“  appears  on  the  text  display  and  the  hour  digits  start 
flashing. With the + or - button you can set the hours.  
Press SET button again and set the minutes by the same way.  

 

Manual date setting: 

 „DATE  SET“  appears  on  the  text  display  and  the  year  starts 
flashing. With the + or - button you can set the year.  
Press  SET  button  again  and  the  month  starts  flashing. With  the  + 
or - button you can set the month. 
Press SET button again and the day starts flashing. With the + or - 
button you can set the day. 

 

 
Main reset (resetting back to factory settings): 

“MAIN  RESET”  appears  on  the  text  display.  If  the  “OK/MAX.MIN.” 
button  is  now  pressed  and  held  for  three  seconds,  the  KlimaLogg 
Pro  deletes  all  settings  and  recorded  data.  The  KlimaLogg  Pro  is 

Summary of Contents for KlimaLogg Pro Pavouk DTHL

Page 1: ...N vod na pou vanie TFA Pav k DTHL Anglicky strana 27 www zahradnejazierka sk...

Page 2: ...records Logging intervals 1 5 10 15 30 minutes or 1 2 3 6 hours Data sets can be called up either directly on the device or using a PC Display of the data sets that have not yet been read out in Up to...

Page 3: ...KlimaLogg Pro These are separately available in specialist shops INSTALLATION AND REPLACEMENT OF THE BATTERIES Note If you have purchased external transmitters you should insert the batteries into th...

Page 4: ...e are manually set After the KlimaLogg Pro has been started up it searches for external transmitters for three minutes After a battery change the transmitters that were entered previously are once aga...

Page 5: ...an one second in one million years The time is coded and transmitted from Mainflingen near Frankfurt via frequency signal DCF 77 77 5 kHz and has a transmitting range of approximately 1500 km Your Log...

Page 6: ...ters that were entered status information current selected channel Text Display Indication of the channel s name or serial number or guidelines Indication Humidity Indication Temperature Memory Indica...

Page 7: ...ld for three seconds go to the basic setting mode of the logger Alarm single press deactivate active alarm sound if an alarm is happend press and hold for three seconds go to the alarm setting mode of...

Page 8: ...rmation and are automatically saved when you leave or go further to the next setting If you press and hold the or button you are quickly taken through the possible settings time date and time zone set...

Page 9: ...mperature unit C F TEMP UNIT appears on the text display and the default C starts flashing With the or button you can select between C or F as the temperature unit Manual time setting TIME SET appears...

Page 10: ...ng the outdoor values After successful start up of the transmitter close the battery compartment carefully In the normal view and as well as in history mode you can scroll up and down through the exis...

Page 11: ...r only three hours after it is started up The transmitter then only transmits its current measured values and can no longer be entered on a receiving device LEARNING MODE Learning mode allows you to m...

Page 12: ...tton during CH1 8 appears in the display All entered transmitters will be deleted DELETED appears in the display You can also delete single transmitters with the HIST DEL button RECORDING INTERVAL SET...

Page 13: ...the respective value was determined are also displayed The corresponding channel number is shown on the channel display and the assigned name or the serial number of an entered transmitter is display...

Page 14: ...least 20 seconds no button Alarm function In case of an alarm Symbol ALARM above the date and the corresponding channel number flashes Also the Hi or Lo Symbol is flashing if the corresponding channel...

Page 15: ...re separately HISTORY MODE You also have the option to read the data sets and the AlarmEvent data sets on the KlimaLogg Pro itself Press HIST DEL button in normal mode HIST appears in the display The...

Page 16: ...s that when all data sets have been written the oldest existing data sets is automatically overwritten by the next new data set On the memory indication the logger displays the amount of data sets tha...

Page 17: ...mpletely filled During radio clock reception communication with the USB receiver is not possible and is interrupted When reception is successful communication is automatically restored again OPEN COLL...

Page 18: ...sure while you plug in any external hardware that this unit is not under electrical power We assume no liability for damage to the KlimaLogg Pro due to incorrect use of the hardware output or for exte...

Page 19: ...e of up to 100 meters to a transmitter and up to 10 meters to the USB transceiver is possible free field in each case In practice the maximum possible range is reduced to the actual range due to local...

Page 20: ...s included as a PDF File within the installation folder of the software POSITIONING OF THE LOGGER The KlimaLogg Pro can be placed on a table or mounted on a wall Before mounting it on a wall ensure th...

Page 21: ...oduct has been manufactured using high grade materials and components which can be recycled and reused Never throw flat batteries and rechargeable batteries in household waste As a consumer you are le...

Page 22: ...mum number of transmitters that can be used 8 Power consumption alkaline batteries recommended 3 x 1 5 V Batterie Typ Mignon AA LR6 Dimensions H x W x D 137 x 98 x 26 mm Weight without batteries 150 g...

Reviews: