background image

 

32

1. 

Insert finger or other solid object 
in the space at the bottom 
center of the battery 
compartment and lift up to 
remove the cover. 

2. 

Insert the batteries, pay 
attention to their correct polarity.  

3.    Insert compartment cover and 

close it. 

 

 
 
 
 
 
 
 

FIRST INSTALLATION: 

When the KlimaLogg Pro is powered up, a short beep will sound and all 
LCD segments will light up.  
 
The KlimaLogg Pro shows the current temperature and humidity values. 
“INDOOR”  is  displayed  in  the  text  field,  and  00:00:00  and  01.01.10  are 
displayed in the  time and  date area (the device counts up the time until 
the  DCF  signal  has  been  received  or  the  time  and  date  are  manually 
set).  
 
After  the  KlimaLogg  Pro  has  been  started  up,  it  searches  for  external 
transmitters  for  three  minutes.  After  a  battery  change,  the  transmitters 
that  were  entered  previously  are  once  again  assigned  the  channel  that 
had previously been assigned to them. External transmitters that had not 
been  previously  detected  are  automatically  entered  on  a  available 
channel. 
 

 
DCF RADIO CONTROLLED TIME RECEPTION  

• 

After the KlimaLogg Pro has searched for external transmitters for 
three minutes, the device begins to search for the DCF signal 
(german radio-controlled clock signal), and the DCF reception 
indicator flashes. If the time code has been received after 5-10 
minutes, the radio-controlled time is displayed and the DCF 
reception indicator remains on the LCD.   

Battery 

compartment 

Connector socket 

Open Collector

 

Summary of Contents for KlimaLogg Pro Pavouk DTHL

Page 1: ...N vod na pou vanie TFA Pav k DTHL Anglicky strana 27 www zahradnejazierka sk...

Page 2: ...records Logging intervals 1 5 10 15 30 minutes or 1 2 3 6 hours Data sets can be called up either directly on the device or using a PC Display of the data sets that have not yet been read out in Up to...

Page 3: ...KlimaLogg Pro These are separately available in specialist shops INSTALLATION AND REPLACEMENT OF THE BATTERIES Note If you have purchased external transmitters you should insert the batteries into th...

Page 4: ...e are manually set After the KlimaLogg Pro has been started up it searches for external transmitters for three minutes After a battery change the transmitters that were entered previously are once aga...

Page 5: ...an one second in one million years The time is coded and transmitted from Mainflingen near Frankfurt via frequency signal DCF 77 77 5 kHz and has a transmitting range of approximately 1500 km Your Log...

Page 6: ...ters that were entered status information current selected channel Text Display Indication of the channel s name or serial number or guidelines Indication Humidity Indication Temperature Memory Indica...

Page 7: ...ld for three seconds go to the basic setting mode of the logger Alarm single press deactivate active alarm sound if an alarm is happend press and hold for three seconds go to the alarm setting mode of...

Page 8: ...rmation and are automatically saved when you leave or go further to the next setting If you press and hold the or button you are quickly taken through the possible settings time date and time zone set...

Page 9: ...mperature unit C F TEMP UNIT appears on the text display and the default C starts flashing With the or button you can select between C or F as the temperature unit Manual time setting TIME SET appears...

Page 10: ...ng the outdoor values After successful start up of the transmitter close the battery compartment carefully In the normal view and as well as in history mode you can scroll up and down through the exis...

Page 11: ...r only three hours after it is started up The transmitter then only transmits its current measured values and can no longer be entered on a receiving device LEARNING MODE Learning mode allows you to m...

Page 12: ...tton during CH1 8 appears in the display All entered transmitters will be deleted DELETED appears in the display You can also delete single transmitters with the HIST DEL button RECORDING INTERVAL SET...

Page 13: ...the respective value was determined are also displayed The corresponding channel number is shown on the channel display and the assigned name or the serial number of an entered transmitter is display...

Page 14: ...least 20 seconds no button Alarm function In case of an alarm Symbol ALARM above the date and the corresponding channel number flashes Also the Hi or Lo Symbol is flashing if the corresponding channel...

Page 15: ...re separately HISTORY MODE You also have the option to read the data sets and the AlarmEvent data sets on the KlimaLogg Pro itself Press HIST DEL button in normal mode HIST appears in the display The...

Page 16: ...s that when all data sets have been written the oldest existing data sets is automatically overwritten by the next new data set On the memory indication the logger displays the amount of data sets tha...

Page 17: ...mpletely filled During radio clock reception communication with the USB receiver is not possible and is interrupted When reception is successful communication is automatically restored again OPEN COLL...

Page 18: ...sure while you plug in any external hardware that this unit is not under electrical power We assume no liability for damage to the KlimaLogg Pro due to incorrect use of the hardware output or for exte...

Page 19: ...e of up to 100 meters to a transmitter and up to 10 meters to the USB transceiver is possible free field in each case In practice the maximum possible range is reduced to the actual range due to local...

Page 20: ...s included as a PDF File within the installation folder of the software POSITIONING OF THE LOGGER The KlimaLogg Pro can be placed on a table or mounted on a wall Before mounting it on a wall ensure th...

Page 21: ...oduct has been manufactured using high grade materials and components which can be recycled and reused Never throw flat batteries and rechargeable batteries in household waste As a consumer you are le...

Page 22: ...mum number of transmitters that can be used 8 Power consumption alkaline batteries recommended 3 x 1 5 V Batterie Typ Mignon AA LR6 Dimensions H x W x D 137 x 98 x 26 mm Weight without batteries 150 g...