background image

13

ScanTemp 410

– Infrared Thermometer 

ScanTemp 410

– Infrared Thermometer 

12

• The measured value and the maximum value (MAX) will be

displayed during the measurement. 

• Release the measuring button 

• On the display appear HOLD and the latest measured tem-

perature for about 15 seconds. 

• Press the °C/°F button 

➊ 

and you can change between

Celsius (°C) or Fahrenheit (°F) as temperature unit.

• When the instrument is not used, it will automatically

switch off after 15 seconds.

6.1 Distance, Spot Size, and Field of View (Fig. 2)

• As the distance (D) from the object increases, the spot size

(S) of the area measured by the unit becomes larger a ratio
D:S = 12:1 (e.g. 120 cm distance = 10 cm spot size). To get
the most accurate temperature reading, aim at the target as
near as possible. 

• Should the distance be too great, there is a risk that the

temperature has also been taken outside the aimed target. 

6.2 Shiny and transparent surfaces

• Not recommended for use in measuring shiny or polished

metal surfaces (stainless steel, aluminum, etc.). To com-
pensate for this, cover the surface to be measured with
masking tape or flat-colored paint and measure the surface.

• The unit cannot measure through transparent surfaces such

as glass or plastic. It will measure the surface temperature
of the glass instead.

7. Care and maintenance

• The sensor lens is the most delicate part of the thermome-

ter. Please protect the sensor part from dirt. Gently clean it
with a soft cloth moistened with water or medical alcohol. 

• Avoid splashes and spills on the unit.
• Store at a temperature of between -20°C to +65°C. 

7.1 Battery replacement

• The battery symbol appears permanently on the display.

• Protect the device from high or abrupt temperature

changes. 

• Do not leave the device near objects of high temperature. 
• Do not immerse the device in water. Water can penetrate

and cause malfunction. Protect it from moisture. 

• Check the housing before using the device. Do not use the

device if it seems to be damaged. Check for cracks or miss-
ing plastic parts.

• Steam, dust, smoke, etc. can obstruct the unit optics and

prevent accurate measurement.

EMC/RFI

• Protect the unit from EMI (Electro Magnetic Interference)

from induction heaters and microwave ovens and Electro
Static Discharge. Readings may be affected if the unit is
operated within a radio frequency electromagnetic field
strength of approximately 3 volts per meter, but the perfor-
mance of the instrument will not be permanently affected. 

4. Features

• Large LCD-display with backlight
• Indication of measured value and maximum value
• Auto power off after 15 seconds
• Switch °C/°F
• With laser pointer

5. How the unit works

• Every body releases 

infrared energy

. The unit’s optics and

detector sense infrared energy and translate this informa-
tion into a digital reading which is displayed. 

6. Use 

(Fig. 1)

• Press and hold the measuring button 

➋ 

to activate the

measuring process.

• The backlight is automatically activated.
• With the laser pointer the measuring point can be focused. 

TFA Anl. No. 31.1115_04_20  09.04.2020  9:37 Uhr  Seite 7

Summary of Contents for 31.1115

Page 1: ...Bedienungsanleitung Instruction manual Mode d emploi Instrucciones de uso Gebruiksaanwijzing Istruzioni per l uso Kat Nr 31 1115 TFA Anl No 31 1115_04_20 09 04 2020 9 37 Uhr Seite 1...

Page 2: ...nkorrekte Messwerte und Folgen die sich aus solchen ergeben k nnen Beachten Sie besonders die Sicherheitshinweise Bewahren Sie diese Bedienungsanleitung gut auf 2 Einsatzbereich Das SCANTEMP 410 Infra...

Page 3: ...r t ist nicht zum Messen der K rpertemperatur geeignet Vorsicht Verletzungsgefahr Das Produkt ist mit einem Laser der Laserklasse 2 ausge stattet Sollte das Hinweisschild auf dem Ger t nicht in Ihrer...

Page 4: ...eine digitale Anzeige 6 Anwendung Fig 1 Dr cken und halten Sie die Mess Taste um die Mes sung zu aktivieren Die Hintergrundbeleuchtung schaltet sich an Mit dem Laservisier kann der Messfleck genau an...

Page 5: ...d Informationen zu Ihrem Produkt finden Sie unter Eingabe der Artikel Nummer auf unserer Homepage www tfa dostmann de 04 20 Er2 Sehr starke Schwankungen der Umgebungstemperatur Er3 Umgebungstemperatur...

Page 6: ...amiliarize yourself with your new device to learn all of its functions and parts to find out important details about its first use and how to operate it and to get advice in the event of a malfunction...

Page 7: ...clean it with a soft cloth moistened with water or medical alcohol Avoid splashes and spills on the unit Store at a temperature of between 20 C to 65 C 7 1 Battery replacement The battery symbol appea...

Page 8: ...As a consumer you are required to take end of life devices to a designat ed collection point for the disposal of electrical and electronic equipment in order to ensure environmentally compatible disp...

Page 9: ...facile utiliser On obtient la temp rature de surface apr s une seconde gr ce la m thode de mesure sans contact galement d objets chauds dangereux et diffi ciles atteindre Le spot mesur peut tre relev...

Page 10: ...appareil ne convient pas pour mesurer la temp rature corporelle Attention Danger de blessure Cet appareil est quip d un laser de classe 2 Si l autocol lant mont sur l appareil n est pas r dig dans la...

Page 11: ...a d c le et traduit l information sur un relev num rique 6 Utilisation Fig 1 Maintenez la touche de mesure appuy e pour activer la mesure L clairage de fond est activ Le spot mesur peut tre relev avec...

Page 12: ...imum Dimension 40 x 72 x 174mm Poids 180 g piles inclues Hi Temp rature 500 C 932 F Lo Temp rature 60 C 76 F Er2 Tr s fortes fluctuations de la temp rature ambiante Er3 La temp rature ambiante n est p...

Page 13: ...metro ad infrarossi SCANTEMP 410 utilizzabile in molti settori Compatto e facile da usare il termometro rile va la temperatura superficiale di un oggetto fra un secon do E possibile rilevare la temper...

Page 14: ...are la misurazione Lo strumento non adatto alla misurazione della tempera tura corporea Attenzione Pericolo di lesioni Il prodotto dotato di un laser di classe 2 Se la seguente etichetta non dovesse e...

Page 15: ...atura attuale per 15 secondi Con il commutatore C F possibile scegliere fra la visualizzazione della temperatura in C gradi Celsius o F gradi Fahrenheit In caso di mancato utilizzo il dispositivo si s...

Page 16: ...a 50 C ed attendere almeno 30 min finch lo strumento si sia rigenerato Er Con tutte le altre segnalazioni d errore si dovrebbe disinserire l apparecchio togliere la batteria per ca 1 minuto e poi met...

Page 17: ...en onderdelen kennen komt u belangrijke details te weten met het oog op het in bedrijf stellen van het apparaat en de omgang ermee en krijgt u tips voor het geval van een storing Door rekening te houd...

Page 18: ...chter van een stuk plak band voorzien of met een matte verf lakken en vervolgens de meting uitvoeren Het apparaat kan niet door transparante oppervlakken zoals glas of plastic meten In plaats daarvan...

Page 19: ...te brengen om een milieuvriendelijk verwijderen te garanderen De benamingen van de zware metalen zijn Cd cadmium Hg kwikzilver Pb lood 7 Schoonmaken en onderhoud De sensor is het gevoeligste onderdeel...

Page 20: ...iormente No emplee el dispositivo de modo distinto al especificado en estas instrucciones No est permitido realizar reparaciones transformaciones o modificaciones por cuenta propia en el dispositivo p...

Page 21: ...arroja El detector ptico la percibe traduciendo la informaci n en una indicaci n digital Precauci n Riesgo de lesiones El producto est equipado con un l ser de Clase II Si la eti queta en el dispositi...

Page 22: ...ara activar la fun ci n de la medici n La iluminaci n de fondo se enciende Con el l ser puede arrumbarse la mancha de medici n Durante la medici n se muestra la temperatura actual y el valor m ximo MA...

Page 23: ...imensione 40 x 72 x 174mm Peso 180 g bater as inclusivas Hi Temperatura mayor de 500 C 932 F Lo Temperatura menor de 60 C 76 F Er2 Oscilaciones muy fuertes de la temperatura ambiente Er3 Temperatura a...

Page 24: ...in la autorizaci n de la TFA Dostmann Los datos t cnicos de este producto corresponden al estado en el momento de la impresi n y pueden ser modifi cados sin previo aviso Los actuales datos t cnicos e...

Reviews: