![Teyme EOLO-GTE10 Instructions Manual Download Page 50](http://html.mh-extra.com/html/teyme/eolo-gte10/eolo-gte10_instructions-manual_1098163050.webp)
50
8. Failures detection
FAILURE
PROBABLE CAUSE
POSIBLE SOLUCIÓN
Pressure blows
Air Suction
Reduce revolutions in the PTO or pressure of the
circuit
Pressure
increase
Obstructed
pressure filters
Clean the circuits
Foam
creation
Air in the circuit
Check o’rings, joints, hoses and suction fittings
Excessive stirring
Reduce revolutions in the PTO or circuit pressure
Check the tension of the safety valve of the self-
cleaning filter.
Make sure that there is return to tank.
Use additive with against-foaming action
Loss of liquid of
the pump
Damaged diaphragms
Replace
Damaged pistons
Replace
The distributor does
not work
Interrupted connection
Check cable rupture
Check that the wires are well-connected
The valves do not
close correctly
Check obstructions in the valves
Check the endings of paths
There is not electrical
current
Wrong polarity. Brown is pos. (+), Blue is neg. (-).
Chec the electrical plate
Check that the fuse makes good contact with your
electrical support.