5. Adjustments and How to Start Up
tart up
32
5.8.2.2.
B Fan
To change the position of the angle of the impeller’s blades the next steps will have to be followed:
1.
Dissassemble the rear grid of the air unit.
2.
Take the hub shell out of the fan.
3.
Loosen slightly the allen screws inside the hub so that the base of the blades could spin.
4.
Take out the positioning red cues of the fan out of their lodge.
5.
Assemble the cues depending on the needed air flow. The plastic cues distinguish themselves for
the graved character A, B, C or D, A standing for 30º inclination and D for 45º one with rises of 5º.
It is compulsory that all cues have the same character.
6.
Turn each blade separately to lodge the cue in its place.
7. Tighten the allen screws of inside the hub of the fan.
8. Assemble the hub shell.
9. Re-assemble the rear protection grid of the air unit. On no
account the PTO must be activated when the grid is not
assembled.
DANGER! All the blades must remain with the same angle, otherwise vibrations will
occur, coming to the breakage of the air unit.
5.8.2.3.
C Fan
To change the position of the angle of the impeller’s blades the next
steps must be followed:
1.
Disassemble the rear grid of the air unit.
2.
Leave out the hubcap (1) previously getting the screws out.
3.
Take all the screws (2) out of the rings’ union, marking out the position
of every one of them to prevent the impeller from getting unbalanced.
4.
Separate both parts of the rings (3) where the blades are attached.
5.
Take out the blades and change the disk (4) placing another with the
corresponding grades.
6.
Re-assemble all the system fastening the pieces in the same position to
avoid unbalance.
7. Re-assemble the rear protection grid of the air unit. On no account the PTO must be
activated when the grid is not assembled.
DANGER! All the blades must remain with the same angle, otherwise vibrations will
occur, coming to the breakage of the air unit.
ATTENTION! Maintain the balance washers laid in the hub of the impeller. We recommend
that after having changed the angle of the blades, the air unit gets balanced anew.