background image

Texmate, Inc. Tel. (760) 598-9899  •  www.texmate.com

Page 14

DL-40JANUS-SG manual (d0116)

BASIC MODEL NUMBER

DL-40JANUS-SG. . . . . . . .96x48, Leopard, 4 Digit, Strain Gage/Pressure. . . . . . . . . . .

Standard Options for this Model Number

 

Order Code Suffix 

Description 

DISPLAY

DR. . . . . .Red LED, 0.56 inch high  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

DB .  .  .  . Super–bright Red LED, 0 .56 inch high .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

DG   .  .  . Green LED, 0 .56 inch high .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

LG .  .  .  . Large Green LED, 0 .8 inch high .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

LR .  .  .  . Large Red LED, 0 .8 inch high   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

POWER SUPPLY

PS1 . . . . .85 - 265VAC / 95 - 300VDC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 

PS2   .  .  . 18 - 48VAC / 10 - 72VDC   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   

INPUT MODULES (Partial List. See www.texmate.com)

Unless otherwise specified Texmate will ship all modules precalibrated with factory 

preselected ranges and/or scalings as shown in 

BOLD

 type

IS01   .  . Strain Gage/Pressure 5/

10V DC

 Exc ., 20/

2mV/V

4

/6-wire

 

ANALOG OUTPUT  

AIV   .  .  . Isolated 14 Bit Voltage Output,  0-10VDC   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

AIC  .  .  . Isolated 14 Bit Current Output, 0-20mA and 4-20mA, pls . specify 

MODBUS RTU RS-485 SERIAL OUTPUT

S485

 .  . Isolated Modbus RTU RS-485 serial output  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

RELAY  OUTPUT

R1. . . . Single 5A Form A Relay  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

R2. . . . Dual 5A Form A Relays   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

RELAY OUTPUT MODULES  

OR11  . . . . . . . One 9 Amp Form C Relay, Isolated. . . . . . . . . . . . . . . . . . 

OR15 . One 9 Amp Form C and Two 4 Amps Form A Relays  . . . . . . . .  

OR16 . One 9 Amp Form C and One 4 Amp Form A Relays . . . . . . . . .

OR12 . Two 9 Amp Form C Relays, Isolated  . . . . . . . . . . . . . . . . . . . . .  

OR14 . Two 9 Amp Form C and Two 4 Amps Form A Relays  . . . . . . . .

OR23 . Two 9 Amp Form C and One 4 Amp Form A Relay, Isolated. . .  

OR31 . One 4 Amp Form A Relay, Isolated  . . . . . . . . . . . . . . . . . . . . . .

OR32 . Two 4 Amp Form A Relays, Isolated  . . . . . . . . . . . . . . . . . . . . .  

OR33 . Three 4 Amp Form A Relays, Isolated  . . . . . . . . . . . . . . . . . . . .  

OR34 . Four 4 Amp Form A Relays, Isolated  . . . . . . . . . . . . . . . . . . . . .  

Solid State Relay (SSR) Output Modules DC Only  

OR51 . One 400V DC Solid State Relay (SSR) 210mA. . . . . . . . . . . . .  

OR52 . Two 400V DC Solid State Relays (SSR) 210mA  . . . . . . . . . . . .

OR53 . Three 400V DC Solid State Relays (SSR) 210mA. . . . . . . . . . .

OR54 . Four 400V DC Solid State Relays (SSR) 210mA. . . . . . . . . . . .

Special Options and Accessories (OA’s) 

 

Part Number Description 

SPECIAL OPTIONS (Specify Inputs or Outputs & Req. Reading)

ZR .  .  .  .  .  .  .  .  .  .  .  .  . Range Change from Standard Range shown in BOLD type 

ZS  .  .  .  .  .  .  .  .  .  . Custom display scaling within standard ranges   .  .  .

ZS-AO   .  .  .  .  .  .  .  .  .  .  .  .Custom scaling of analog output for digital meters & bargraphs .

ACCESSORIES (Specify Serial # for Custom Artwork Installation)

75-DBBZ9648F .  .  .  .Black Bezel for 96x48mm Case .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

75-DMTCLIPF   .  .  .  .Side Slide Brackets (2 pc) - extra set, extra strength   .  .

76-DL40G-N4  .  .  .  .  ."Touch" Green LED Faceplate, NEMA 4, Factory install 

76-DL40LG-N4  .  .  .  ."Touch" Large Green LED Faceplate, NEMA 4, Factory install 

76-DL40LR-N4  .  .  .  ."Touch" Large Red LED Faceplate, NEMA 4, Factory install 

76-DL40R-N4  .  .  .  .  ."Touch" Red LED Faceplate, NEMA 4, Factory install .  .  

ART-FS-S/D   .  .  .  .  .  .NRC for artwork & set-up Faceplate/Desc .  .  .  .  .  .  .  .  .  .  .

ART-FS-001   .  .  .  .  .  .Install Custom Faceplate per meter - 1 color .  .  .  .  .  .  .  .  .

OP-MTLCLIP   .  .  .  .  .Screw Mounting Clips (2 pc) - to screw tighten slide brackets  

OP-MTL96X48  .  .  .  .Metal Surround Case, includes screw mounting clips  .  .

OP-N4X/96X48 .  .  .  .96x48mm clear lockable front cover–NEMA 4X, splash proof    

Prices subject to change without notice.

BASIC MODEL #

DISPLAY

POWER SUPPLY

INPUT MODULES

ANALOG OUTPUT*

RELAY OUTPUT*

OPTIONS / ACCESSORIES

OA____

DL-40JANUS-SG

Add to the basic model number the order code suffix for each standard option required. The last suffix is to 

indicate how many different special options and or accessories that you may require to be included with this 

product. Please see our website, www.texmate.com to configure a meter and see current pricing.

Ordering Information

WARRANTY

Texmate warrants that its products are free from defects in material and workmanship under 

normal use and service for a period of one year from date of shipment. Texmate’s obligations 

under this warranty are limited to replacement or repair, at its option, at its factory, of any of 

the products which shall, within the applicable period after shipment, be returned to Texmate’s 

facility, transportation charges pre-paid, and which are, after examination, disclosed to the sat-

isfaction of Texmate to be thus defective. The warranty shall not apply to any equipment which 

shall have been repaired or altered, except by Texmate, or which shall have been subjected 

to misuse, negligence, or accident. In no case shall Texmate’s liability exceed the original pur-

chase price. The aforementioned provisions do not extend the original warranty period of any 

product which has been either repaired or replaced by Texmate.

USER’S RESPONSIBILITY

We are pleased to offer suggestions on the use of our various products either by way of printed 

matter or through direct contact with our sales/application engineering staff. However, since 

we have no control over the use of our products once they are shipped, NO WARRANTY 

WHETHER OF MERCHANTABILITY, FITNESS FOR PURPOSE, OR OTHERWISE is made 

beyond the repair, replacement, or refund of purchase price at the sole discretion of Texmate. 

Users shall determine the suitability of the product for the intended application before using, 

and the users assume all risk and liability whatsoever in connection therewith, regardless 

of any of our suggestions or statements as to application or construction. In no event shall 

Texmate’s liability, in law or otherwise, be in excess of the purchase price of the product.
Texmate cannot assume responsibility for any circuitry described. No circuit patent or software 

licenses are implied. Texmate reserves the right to change circuitry, operating software, speci-

fications, and prices without notice at any time.

          1934 Kellogg Ave. Carlsbad CA 92008 USA

Tel: 1-760-598-9899 • USA 1-800-839-6283 • That’s 1-800-TEXMATE

• Email: [email protected] • Web: www.texmate.com 

Texmate also has a branch in Taiwan. 

DL-40JANUS-SG Technical Manual Copyright © 2021 Texmate Inc. All rights 

reserved. Published by: Texmate Inc. USA. Information in thisTechnical Manual 

is subject to change without notice due to correction or enhancement.

The information described in this manual is proprietary to Texmate, Inc. and 

may not be copied, reproduced or transmitted, in whole or in part, in connec-

tion with the design, manufacture, or sale of apparatus, device or private label 

product without the express written consent of Texmate, Inc.

Summary of Contents for DL-40JANUS-SG

Page 1: ...utput Range Setting and Calibration 6 General Features Specifications Software Features Index LEOPARD FAMILY DL 40JANUS SG Two scaling methods MANUAL no external sig nal source required and AUTO requi...

Page 2: ...by pressing and releasing the or buttons When there are more than two display selec tions they are shown in brackets below the first display and are also selectable by press ing and releasing the or b...

Page 3: ...L POINT AND BRIGHTNESS SELECTION See Page 6 Setpoint 3 SP3 Setpoint 4 SP4 Valley Offset Scale Factor Calibrate Analog Output Lo Calibrate Analog Output Hi X XXX XX XX XXX X XXXX XXXX 2 3 4 Decimal Poi...

Page 4: ...t STEP B Select Between Calibration of Input or Output Note If the analog output option is not present Step B is skipped and the program goes directly from Step A to Step C 1 Press the or button to se...

Page 5: ...Point Analog Output Note If the analog output option is not present Step B is skipped and the program goes directly from Step A to Step C 1 Press the or button to select the display toggling from CAL...

Page 6: ...s the P and buttons at the same time Display toggles between CAL and oFF 2 Press the P button Display shows previous dP selection STEP E Set the Decimal Point 1 Using the and adjust the display to the...

Page 7: ...unts and does not include the deci mal point If you need the decimal value with decimal point you will need to read the register convert it to decimal read 40024 see below to determine decimal locatio...

Page 8: ...ST2 Setpoint 2 Hysteresis setting 40019 0x0012 SINT16 R W 1999 9999 PRES3 Setpoint 3 setting 40020 0x0013 UINT16 R W 0 9999 HYST3 Setpoint 3 Hysteresis setting 40021 0x0014 SINT16 R W 1999 9999 PRES4...

Page 9: ...P2 Delay on Make doM Delay Time Setting STEP H Set the SP2 Delay on Break dob Delay Time Setting STEP I Set the Hysteresis Setting for Setpoint 2 1 Using the and buttons adjust the display to the desi...

Page 10: ...with external signal OFF 17 16 19 19 18 MANUAL rescaling ON AUTO scaling OFF ON SP1 NO SP1 NO SP2 NO SP2 NO Pins 14 and 15 AC DC Power Input Auto sensing AC DC power supply For voltages between 85 265...

Page 11: ...air circulation 3 Separate input output leads from power lines to protect the meter from external noise Input output leads should be routed as far away as possible from contactors control relays tran...

Page 12: ...71 1 8 DIN Cutout spacers 87 4mm 3 45 Various bezel colors are available Black is standard Prog SP3 SP4 SP2 SP1 For additional strength extra Mounting Slide Clips can be ordered and doubled up one beh...

Page 13: ...se is made from fire retardant polycar bonate A metal surround case can be ordered to enhance the meter s fire retardant capabilities and also provide shielding against electromagnetic interference EM...

Page 14: ...OA____ DL 40JANUS SG Add to the basic model number the order code suffix for each standard option required The last suffix is to indicate how many different special options and or accessories that you...

Reviews: