Set Up Timer Delay Settings
Delay-on-break (DOB)
time 0.1 to 6553.5 secs
Reset SPC_X to [XX0]
Minimum on-time (M_on) 0.1 to
6553.5 secs
On-time (on_t) 0.1/0.001
to 6553.5/65.535 secs
On-time (on_t) 0.1/0.001
to 6553.5/65.535 secs
On-time (on_t) 0.1/0.001 to
6553.5/65.535 secs
dob 0.1 to 6553.5 secs
DOB 0.1/0.001 to
6553.5/65.535 secs
Off-time (oFF_t) 0.1/0.001
to 6553.5/65.535 secs
Off-time (oFF_t) 0.1/0.001
to 6553.5/65.535 secs
Minimum off-time (M_of)
0.1 to 6553.5 secs
Programming Tip
If you do not require any
of the functions in this
mode, ensure it is set to:
Resolution setting
applies to SP1/SP2
ONLY
Normal Mode
Resolution setting
applies to SP1/SP2
ONLY
Resolution setting
applies to SP1/SP2
ONLY
Resolution setting
applies to SP1/SP2
ONLY
3rd digit set
to [XX6]
Delay-on-make (DOM)
time 0.1 to 6553.5 secs
DOM 0.1 to 6553.5
secs
Off-time (oFF_t) 0.1/0.001 to
6553.5/65.535 secs
1-Shot ON Mode
Single Actuation
Pulse ON Mode
Single Actuation
Repeat ON Mode
Multiple Actuation
Normally OFF/
Pulsed ON
Normally ON/
Pulsed OFF
1-Shot OFF Mode
Single Actuation
Pulse OFF Mode
Single Actuation
Repeat OFF Mode
Multiple Actuation
DOM 0.1/0.001 to
6553.5/65.535 secs
S
e
t
p
oi
n
t
P
r
og
r
a
mm
i
n
g
M
o
d
e
c
o
n
ti
nu
e
d
P
[diSP]
[rESLt]
[Ch1]
[Ch2]
[Ch3]
[Ch4]
[tot_1]
[tot_2]
[PEAK]
[VALEY]
[tArE]
[244 to 1]
P
P
P
Use the
and
buttons to cycle
through the options
[brEAK]
[both]
[LEVEL]
Sets from 0 to
–
19999
Use the
but-
tons to cycle through
the Registers Menu
and Registers (1 to
244) to select which
destination register
is to be reset by a
setpoint (also see
page 48).
[i-S+C]
[d+C]
[rEG]
Sets from 0 to 99999
Select Reset Destination Register
Select Trigger Setting
Select Reset Mode
Select Reset Constant
P
Select Print Triggered by Setpoint
P
Select Log Triggered by Setpoint
Set Up Register Reset and Setpoint Trigger Functions
Third digit
set to [XX7]
Selecting any
d e s t i n a t i o n
register takes
you to Mode
Reset
Selecting [oFF] in the
Destination Register
Reset Setup takes
you to Setpoint Print
Trigger Setup
P
Use the
but-
tons to cycle through
the Registers Menu
and Registers (1 to
244) to select which
register
’
s contents
are to be copied into
the destination regis-
ter by a setpoint
(also see page 48).
X
X
X
X
Reset SPC_X to [XX0]
P
Programming Tip
If you do not require any
of the functions in this
mode, ensure it is set to:
Select
[rEG]
to
access the source
parameter to select
the number of the
Modbus register in
the meter to be
copied to the reset
destination register
[diSP]
[rESLt]
[Ch1]
[Ch2]
[Ch3]
[Ch4]
[tot_1]
[tot_2]
[PEAK]
[VALEY]
[tArE]
[244 to 1]