Premier Elite 8XP-W & 32XP-W Installation Manual 

INS467-8 

System Requirements 

To  enable  all  of  the  advanced  functionality  and  diagnostics  capability  for 

Ricochet  V3

  the  following  are 

minimum requirements:- 

 

Wintex™

 Version 6.2 Build 4 or later 

 

Ricochet Monitor™

 0.2.18.5.1 or later 

 

Premier Elite™ Series

 V4.xx or later 

 

Premier Elite™ 32XP

-W & 8-W 

Expanders V3.xx or later 

 

Expander firmware version can be found on the round green sticker located on the RH side of the PCB.

 

System Design Considerations 

To ensure correct setup and operation of the Wireless Network it is important that the following procedures 

are used when learning and placing devices. 

Multiple Expander Systems 

When  using  multiple  expanders  great  care  should  be  taken  when  designing  the  system.  Each  expander 

should  be  treated  as  its  own  wireless  network;  it  is  not  possible  for  devices  to  hop  from  one  wireless 

network  to  the  other;  it  is  also  not  possible  for  expanders  to  pass  wireless  signals  from  devices  not 

assigned to them and nor can the expanders talk to each other. 

Learning Devices 

All  devices  should  be  learnt 

before

  they  are  placed  in  their  final  location.  The  expander  should  be  in 

commission mode, please see page 24.This will ensure that they are registered on the receiver or control 

panel, and that Mesh Networks and routing are established correctly. Please refer to the relevant section in 

this document to Learn Devices to the system. 

Learning Premier Elite SmartKey™

 

Premier  Elite  SmartKey™

  should  only  be  learned 

AFTER

  all  devices  and  expanders  are  in  their  final 

location, this is critical on larger systems where multiple expanders are being used 

 

Devices should be at least 30cm’s away 

but no further than 10m from the receiver when being learned. 

 

Placing Devices 

Once  all  of  the  devices  have  been  learnt,  they will  need  placing  in  their  desired  location,  this  should  be 

done by installing devices closest to the expander first and then working outwards so that the last devices 

installed are those furthest away from the expander.  
Make sure to install devices with the expander in Commission mode. See page 24. 
Devices also have a commission mode which will indicate a secure and valid path of communication to the 

receiver. See page 24. 

 

You  should  wait  at  least  20  minutes  after  installing  the  last  device  to  make  sure  routing  has  been  correctly 

established between all system devices.

 

 

For  maximum  reliability  and  system  integrity  avoid  long  and  thin  set-ups.  Do  not  mount  devices  on  or  near 

metal. Keep devices away from mains electricity supplies.

 

 

Devices are capable of hopping through up to two other devices, or a maximum of three hops.

 

 

 

 

 

Summary of Contents for Premier Elite 32XP-W

Page 1: ...Installation Manual Premier Elite 8XP W Premier Elite 32XP W INS467 8...

Page 2: ...Key 16 Premier 412 816 V9 5 V11 10 Later Premier 832 2 5 V4 10 Later 17 Option Switch Settings 17 Expander Settings 17 Removing Detectors 18 Learning SmartKey 18 SmartKey 19 Learning Devices directly...

Page 3: ...stalled SignalSecurity further enhances network reliability with each device already aware of the number of communication paths available to it The 8XP W 32XP W expanders can be used on any premier co...

Page 4: ...88 168 640 to V4 X X Relearn if you Flash Elite 12 W 24 W 48 W to V4 X X V2 X X V3 X X All Versions Yes No No V4 X X 1 X X 2 X X Yes No No 3 0 6 No No No V3 Multiple Expander Support V2 introduced mul...

Page 5: ...that they are registered on the receiver or control panel and that Mesh Networks and routing are established correctly Please refer to the relevant section in this document to Learn Devices to the sy...

Page 6: ...Legacy Contact Technical Support for a Legacy Manual Ensure all Option Switches are off See Page 7 Learn Devices to Control Panel See Page 10 Onwards set attributes See Page 10 Onwards Place Devices...

Page 7: ...tions Switch Use to select the receiver functionality depending on panel firmware Switch 1 ON firmware dependant please see the relevant programming section Switch 2 ON Legacy Mode OFF Ricochet Switch...

Page 8: ...an be used for most installations However under certain conditions it may be necessary to use screened cable Selecting an Address Each expander must be assigned a different address using the DIL switc...

Page 9: ...N A N A N A N A N A N A N A N A N A N A N A N A N A N A Premier Elite 168 Exp 1 Exp 2 Exp 1 Exp 2 N A N A N A N A N A N A N A N A N A N A N A N A Expander Address 1 5 1 5 N A N A N A N A N A N A N A N...

Page 10: ...ed Ricochet learn menu accessible via the key when in Engineer menu This new feature is only for devices SmartKey should be learnt to the system in the User Menu as described later in this section Lea...

Page 11: ...pe Area When learning devices if no editing has taken place of the control panel onboard hardwired zones these will be switched to Not Used after the first Ricochet device is learned to the system the...

Page 12: ...se this key to exit the Learn Menu Premier EliteV2 00 V2 09 24 48 88 168 640 Ricochet V2 xx Option Switches All Off Introduction V2 xx firmware added the option to learn Ricochet devices through the Z...

Page 13: ...is the default mode for all single technology motion detectors Hybrid Mode Hybrid mode is used to control the reporting functions for devices When in this mode devices are awake only when the system...

Page 14: ...n Learning 20s Zone 00 Learn P R P 0 0 y Zone 00 P0 0 Not sed n n y Zone 00 Attrib y Zone 00 Attrib2 A Zone 00 Areas A y Zone 00 Text n n y Zone 00 Chime Silent n n y Zone 00 Test Remote Test Off n n...

Page 15: ...on Whilst it is possible to learn at any point during the programming of the system learning and testing the functionality of the Premier Elite SmartKey after all devices have been placed will ensure...

Page 16: ...A Please refer to page 27 for details of the LED AUX funtions To disable two stage arming please refer to INS176 8 or later and check Global Options System Config options 38 48 Once the 16 slots on a...

Page 17: ...r s mode by entering the engineer code followed by then 2 Enter to select the Assign Radio Device menu if an error tone is generated then the receiver is not installed or configured correctly 3 Enter...

Page 18: ...e receiver and work downwards The users available will vary depending on the control panel Control Panel Available Users Premier 412 Users 1 to 31 Premier 816 Users 1 to 31 Premier 832 Users 1 to 63 S...

Page 19: ...he SmartKey from e g 4 Press the key the panel will generate an acceptance tone and the SmartKey is no longer assigned to the selected user Note If the SmartKey was assigned to user 02 onwards the use...

Page 20: ...ter Engineer Utilities now includes a new Ricochet Diagnostics menu This menu displays information about the live system and is split into Premier Elite SmartKey and Ricochet devices via Zones and Use...

Page 21: ...ion from the device was over an hour ago Zone 00 P R No msg recvd yet This display shows that no message has been received yet this would normally be seen on a recently powered up system wait 15 minut...

Page 22: ...ed onto the system ser002 Ricochet Partarm Bat OK Shows the different messages displayed when the relevant buttons are pressed ser002 Ricochet Disarm Bat OK ser002 Ricochet ullarm Bat OK ser002 Ricoch...

Page 23: ...Zone 00 Shock Status aaaSpdtt Zone 00 Shock P Zone 00 Shock P C Zone 00 Not Ricochet C B ser000 Ricochet Not Ricochet U ser002 Ricochet Not connected Zone 00 Shock C Zone 00 Shock hr since msg C C se...

Page 24: ...nabled when the expander is in tamper When in commission mode the RF signal is attenuated by 6 dB and will reject weak signals This means that when devices are placed into their final locations and co...

Page 25: ...being used to trigger 24 hour circuits or where the zone is required to chime ensure the device attributes are at the default Always Awake as detailed on page 26 The two additional inputs may also be...

Page 26: ...W and Impaq Plus W For example a Impaq Contac W on a door which you need to know is opened regardless of system state or devices such as PA buttons smoke detectors which have been connected to the in...

Page 27: ...xiliary devices from the control panel outputs The function keys should first be enabled either from the Engineers Keypad or Ricochet Monitor Once enabled the user can enter Auxiliary mode by pressing...

Page 28: ...ee alarm status LED s will flash to indicate an arm failure In the case of users assigned to multiple areas the whole system should be unset and each area investigated to determine the cause of the ar...

Page 29: ...g Voltage 10 13 7VDC Current Consumption 120mA Network 4 wire standard 7 0 2 alarm cable up to 250m Star Daisy Chain or any combination Outputs 1 8 Not Used Operating Temperature 10 C 14 F to 50 C 122...

Page 30: ...II Hereby Texecom declares that the radio equipment type GCA1000 2 and GCD1000 2 Premier Elite 32XP W and Premier Elite 8XP W is in compliance with Directive 2014 53 EU The full EU declaration of conf...

Page 31: ...Premier Elite 8XP W 32XP W Installation Manual INS467 8 31 Notes...

Page 32: ...Lancashire BB4 4PW England Technical Support UK Customers Tel 08456 300 600 Calls charged at local rate from a BT landline Calls from other networks may vary International Customers Tel 44 1706 233875...

Reviews: