Premier Elite 8XP-W & 32XP-W Installation Manual
INS467-8
13
Zone 00 Learn:
PR P-0,0
Fig 2
If you are unsure if a zone already has a device learned to it, you can go to the menu as in Fig 1, press
/
and then
n
/
n
if a device is already learnt the display will look like Fig 2, if not then it will
look like Fig 3
Zone 00 Learn:
ree P-0,0
Fig 3
Please see the diagram on the next page to learn devices.
Deleting Devices
To delete devices from the expander is the same as learning them; choose the zone you wish to delete, and
follow the procedure to learn the device, when the screen shows “Learning” press
/
.
To default the expander completely put option switch 1 & 2 to ON and hold the white programming button until
the expander programming LED's all illuminate and turn off.
Device Modes of Operation
Always Awake
This mode should only be used on devices which are required to signal at all times and is the default setting
for perimeter detection devices such as Contacts and Shock sensors & PA Buttons.
Auto Mode
When in Auto Mode, devices poll at 15 minute intervals. Following activation, devices will not transmit the
same activation again for a period of 3 minutes. This mode of operation is the default mode for all single
technology motion detectors.
Hybrid Mode
Hybrid mode is used to control the reporting functions for devices. When in this mode devices are awake only
when the system is set. Devices are woken up by the control panel at the point of arming. The system will
display "Preparing to Arm". When the system is disarmed the devices will be put back to sleep. This mode of
operation is the default mode for all Dual Technology motion detectors.
On very large systems (100 d) a small delay may be experienced when arming the system, this is normal
as the expanders on the system wake up the relevant devices.
Premier Elite DT-W should ALWAYS be used in Hybrid mode, failure to do this will have an adverse affect on
battery life.
Device Specific Mode
Device Specific mode is used to control the reporting functions for devices. Devices that use this mode of
operation have specific operating parameters and should not be altered. This mode of operation is the default
mode for all Fire detectors (Smoke, Heat and any other variant), & Internal/External Sounders.
Expander O/P Mode
Expander O/P modes are for future use and should not be used with any of the devices listed above.
Zone Types & Attributes
Detailed instructions for programming can be found in INS176-8 or later.
To Learn Devices through the Zone Setup menu please follow the diagram on the next page.