Premier Elite 8XP-W & 32XP-W Installation Manual
INS467-8
17
Premier 412/816 V9.5 &V11.10 & Later, Premier 832 2.5 &V4.10 &
Later
Follow these instructions to learn devices to the system, once completed follow the relevant section of the
control panel manual to programme zones and user attributes.
For V9.5 & V2.5 the number chosen for learning will determine the device slot taken on the expander. This should
always be started at 01. If started at 05 for example, the next devices will go to 06 and you may run out of device
slots.
For V16 panels all Ricochet devices including SmartKey now take the next available slot.
Option Switch Settings
For this version of firmware all option switches 1,2 & 4 should be OFF.
Expander Settings
The expander should be set to address 1.
Detectors are assigned to zones as follows:
1.
Select engineer’s mode by entering the engineer code followed by
/
then
.
2.
Enter
to select the
Assign Radio Device
menu, if an error tone is generated then the
receiver is not installed or configured correctly.
3.
Enter the two digit zone number that you want to assign the detector to e.g.,
*
.
4.
Press the learn switch or short the learn pins and insert the battery. The panel will generate an
acceptance tone and the detector is now assigned to the selected zone.
5.
Program the zone type and attributes as required.
Note:
The Zone Wiring must be programmed as
“Double EOL”, i
f a tamper response is required from the detector.
6.
Repeat steps 2 - 5 for other detectors.
*
When using a Premier Elite 8XP-W devices can only assigned to Zones 1-8 when learning. Using Wintex the
learned Zones can be changed to any that are available.
Programming Menu
Enter Code > ??
Assign 00 Radio
Enter Zone No.??
Enter Zone
Number
??
Assign ?? Radio
Activate Devic20
Enter Engineers code
Then press
then
????
Acceptance Tone
from Panel
Press learn Switch or short learn