Premier Elite 8XP-W & 32XP-W Installation Manual
INS467-8
25
Device Specific Functions
All devices
All settings & mounting height recommendations are covered in the relevant device manual.
Impaq Plus-W
Sensitivity and device placement instructions are covered in the device manual.
Impaq Contact-W
The
Impaq Contact-W
has 3 additional inputs labelled MAG 1 COM MAG 2, these inputs can be used for any
N/C device. If the Reed switch is disabled the device can be used as a transmitter for any device wired into
one of the two inputs.
The two additional inputs are NOT independently programmable of the reed switch, when mapped to a panel
zone if either the reed switch or any of the inputs are triggered the zone which the device is mapped too will
go active.
Switch 3
on the expander controls how MAG 2/COM reports to the control panel. By default the switch is OFF
and anything connected to MAG 2/COM will report as a tamper. When switch 3 is ON MAG 2/COM will report
as alarm.
In the case of the
Impaq Contact
–
W
being used to trigger 24 hour circuits, or where the zone is required to
chime, ensure the device attributes
are at the default “
Always Awake
”
as detailed on page 26.
The two additional inputs may also be used to transmit N/C signals from any other locally powered or self-
powered device, depending on the type of device used you should choose the device attributes to suit.
Walktest Mode
Walktest Mode can be initiated from the Control Panel, Engineers Keypad,
RICOCHET Monitor
or directly on
the expander.
When in Walktest mode LED’s are enabled and the
response time for devices between activations is reduced
to 10 seconds. Walktest will last for 1 hour.
Control Panel
Please refer to the Control Panel installation instructions to enter Walktest mode. The countdown timer does
NOT appear on the panel’s keypad.
Expander
Option switch 4 toggles Walktest mode on and off. To enable Walktest mode from the expander switch
Option switch 4 to the ON position. To leave Walktest mode turn option switch 4 OFF. The countdown timer
will be visible on the engineer’s keypad or
Ricochet
Monitor
.
Engineers Keypad
See page 25. The countdown timer will appear.
Ricochet Monitor
Press the
button. The countdown timer will appear.